As the data entry commands are executed they will be written to the database in
ascending order in a circular addressing fashion from 0x0000 to 0xFFFF, and conversely
when triggers occur entries will retrieved in a FIFO manner - the oldest unused database
entry will be used first.
Four other commands will affect the database.
RESETBUFFER is somewhat self explanatory - all entries in the database will be reset
to NULL length and the available buffer entry count will be set to zero.
READBUFFER - All data in database will be reported - user should be aware this could
result in a very long communication stream if the generate command has been used to fill
a large number of database structures
GETBUFFERCOUNT will return the number of currently filled but unused database
structure entries
AUTOCLEAR=<ON or OFF> controls the behavior of the buffer when the system
triggering is enabled/disabled through a ENGAGE or DISENGAGE. If it is ON any
transition from ENGAGE to DISENAGE or vice versa will result in a RESETBUFFER
being executed.