Cut Sheet
Table Of Contents
- T&B Fitting
- Product Overview
- Rigid & Intermediate Metal Conduit Fittings
- Form 7, Form 8, Series 35, Conduit Outlet Bodies & Covers
- Mogul Conduit Outlet Bodies
- FS/FD Cast Device Boxes and Covers
- Conduit Outlet Boxes
- Conduit Outlet Elbows, Reducers, Plugs, and Adapters
- Three-Piece Couplings
- Sealing Fittings
- Kopr-Shield Compound
- Jacketed Metal Clad Cable Termination Fittings
- Tray Cable Fittings
- EMT Fittings
- Liquidtight Flexible Metal Conduit Fittings
- Shureflex™ Nylon Conduit System
- XTRA FLEX System
- Flexible Cord and Cable Fittings
- Flexible Cord and Cable Fittings - Non-Metallic
- Service Entrance Cable Fittings
- Metal Clad Cable, Armored Cable and FlexibleMetal Conduit Fittings
- Non-Metallic Sheathed Cable Fittings
- Conduit Dimensional Data
Liquidtight Flexible Metal Conduit Fittings
A-114
United States
Tel: 901.252.8000
800.816.7809
Fax: 901.252.1354
Technical Services
Tel: 888.862.3289
www.tnb.com
Standard Liquidtight Female Hub Adapter
CAT.
CONDUIT DIMENSIONS (IN.)
NO.
SIZE A B
5271
†
3
⁄8"1
5
⁄32 1
9
⁄16
5272
†
1
⁄2"1
3
⁄8 1
11
⁄16
5273
†
3
⁄4"1
21
⁄32 1
3
⁄4
5274
†
1" 1
7
⁄8 2
1
⁄8
5275
†
1
1
⁄4"2
9
⁄32 2
1
⁄2
5276
†
1
1
⁄2"2
3
⁄4 2
11
⁄16
5277
†
2" 3
15
⁄32 3
1
⁄16
†
UL Listed as grounding means under NEC 351-7.
Wiremesh Grips for Liquidtight Fittings
CAT.
CONDUIT
LIQUIDTIGHT CONNECTORS
90°
NO.
SIZE STRAIGHT 45° 90° CHASE CHASE ADAPTER
WMG-LT1
3
⁄8" 5331 5341 5351 5361 5371 5271
WMG-LT2
1
⁄2" 5332 5342 5352 5362 5372 5272
WMG-LT3
3
⁄4" 5333 5343 5353 5363 5373 5273
WMG-LT4 1" 5334 5344 5354 5364 5374 5274
WMG-LT5 1
1
⁄4" 5335 5345 5355 5365 — 5275
WMG-LT6 1
1
⁄2" 5336 5346 5356 5366 — 5276
WMG-LT7 2" 5337 5347 5357 5367 — 5277
WMG-LT8 2
1
⁄2" 5338 5348 5358 5368 — 5278
WMG-LT9 3" 5339 5349 5359 5369 — 5279
WMG-LT10 4" 5340 5350 5360 5370 — 5282
Order wiremesh grip separately: no need to duplicate inventory.
UL File No. E23018 CSA File No. 2884 & 4484
Nylon Insulated CHASE
®
Connectors
CAT.
CONDUIT DIMENSIONS (IN.)
NO.
SIZE A B C
5361
†
3
⁄8"1
3
⁄32 1
3
⁄8
1
⁄8
5362
†
1
⁄2"1
3
⁄8 1
3
⁄8
3
⁄16
5363
†
3
⁄4"1
11
⁄16 1
5
⁄8
1
⁄4
5364
†
1" 2
1
⁄32 2
1
⁄16
1
⁄4
5365
†
1
1
⁄4"2
3
⁄8 2
3
⁄8
5
⁄16
5366
†
1
1
⁄2"2
15
⁄16 2
3
⁄4
3
⁄8
5367
†
2" 3
9
⁄16 3
3
⁄8
5368
†
2
1
⁄2"4
3
⁄8 3
15
⁄16
7
⁄16
5369
†
3" 5
1
⁄8 4
1
⁄8
1
⁄2
5370
†
4" 5
1
⁄8 4
1
⁄8
1
⁄2
With SAFE-EDGE
®
ground cone and double bevel sealing ring (through 2").
B
A
C
Nylon Insulated 90° Angle CHASE
®
Connectors
CAT.
CONDUIT DIMENSIONS (IN.)
NO.
SIZE A B C
5371
†
3
⁄8"1
1
⁄32 1
1
⁄2
3
⁄16
5372
†
1
⁄2"1
15
⁄64 1
15
⁄32
3
⁄16
5373
†
3
⁄4"1
31
⁄64 1
7
⁄8
9
⁄32
5374
†
1" 1
23
⁄32 2
1
⁄4
11
⁄32
With SAFE-EDGE
®
ground cone and double bevel sealing ring.
NOTE: UL Listed Liquidtight; & CSA certified watertight. Suitable for hazardous locations use in Class I, Div. 2; Class II, Div. 1
and 2; Class III, Div. 1 and 2, where general purpose equipment is specifically permitted per NEC Section 500-2(a).
†
UL listed as grounding means under NEC 351-7.
Malleable iron
Prevents severe conduit bends and pullout!
Steel or malleable iron with O-Ring Seal