Cut Sheet
Halogen Free
—
Features & Benefits:
• Meets UL 514B and CSA C22.2, No. 18.3 for liquid-tight fittings
• Full compliance to IEC 61386-1, -23 requirements, CE Certified
• Trade sizes from ” to 6” (12mm to 153mm)
• Insulated and non-insulated versions
• Straight, 45° and 90° conduit bodies
• NPT, ISO Metric and PG thead types
• Coordinated performance with T&B Liquidtight Systems Flexible Metallic Conduits
• Ingress protection ratings aligned with industrial enclosures
• Safe Edge® ground cones provide superior bonding
• Double Bevel Sealing Ring eases assembly and insures seal tight performance
• Heat curled insulators protect wire sheathing from damage
• Revolver® grounding version with GR part number suffix
—
Applications:
• Used where liquid-tight flexible metallic raceway is installed in outdoor or indoor locations,
and exposed to continuous or intermittent moisture
• Used to positively bond flexible liquid-tight flexible metallic conduit to boxes or enclosures
• Typical applications include raceway for general purpose industrial and commercial
construction, Machine OEMs, panel builders, indoor and outdoor installations
• Liquid-tight applications against water, oils, cutting fluids, mild acids
• For use in electrical circuits up to 1,000 V
• Suitable for use in Class 1 Division 2, Class 2 Division 1 & 2 Hazardous Locations per
NEC® Section 500
—
Construction / Material / Finish:
• Trade sizes ” to 1” Steel with Zinc Chromate finish
• Trade sizes 1-1/2 to 6” malleable iron with Zinc Chromate finish
• Zinc plated Steel ground cones
• Thermoplastic nylon seal rings
• Thermoplastic nylon heat curled insulators protect wire sheathing from damage
• Halogen Free seal rings, insulators and seal gaskets
• Tempered Cast Locknuts with teeth for vibration resistance
—
Environment ratings:
Working Temperature:
• UL: Gen: -20 to +105°C (-4 to +221°F)
• CSA: Gen: -20 to +105°C (-4 to +221°F)
• IEC/CE: Gen: -25 to +105°C (-13 to +221°F)
—
Chemical Resistance Guide:
• See Publication TDS000081 (Fittings: Steel, Iron & PA66 Polyamide)
• See Publication TDS000117 (Liquid-tight Flexible Metal Conduits)
—
Conforms to:
• UL 514B, Fittings for Cable and Conduit
– File: E23018
• CSA C22.2, No. 18.3, Outlet and Conduit Boxes, Fittings and Accessories
– File: LR-2884, LR-4484
• IEC/EN 61386-1, -23, Conduit Systems for Cable Management
– EU DoC: EC-012-7185
• RoHS (Restriction of Hazardous Substance directive)
• NEMA FB-1 (Fittings and Conduit Bodies)
• JIC EGP1 (Electrical standard for GP machine tools)
• JIC EMP1 (Electrical Standard for Mass Production Engineering)
• Federal Specification A-A 50552 (Fittings for flexible conduit)
• Federal Specification H-28 (Threads)
—
Ingress Protection:
• Provides “Ingress Integrity” between enclosures, fittings, conduits & seals when using
Series 52/53 liquid-tight fittings and T&B Liquidtight Systems LFMC
• Covers all trade sizes from ” to 4” (12mm to 103mm)
• Ingress ratings require use of Series 5260 Seal Gaskets
UL, CSA & NEMA system ingress ratings:
• UL Listed type ratings tested to UL 50E requirements with UL Listed LFMC
• UL File No.: E23018
– Indoor: Type 4, 12, 13
– Outdoor: Type 3, 3R, 4
• CSA C22.2, No. 94.2: Type 3, 3R, 4, 12, 13
• NEMA 250: Type 3, 3R, 4, 12, 13
IEC system ingress ratings:
• IP Ingress Protection per IEC 60529 requirements
• IEC Ingress Ratings: IP66, IP67
—
Standards requirements:
Designed to UL 514B and CSA C22.2, No. 18.3 test requirements including:
• Assembly, Pull, Resistance, Oil spray, Polymer durability, Flammability Coating thickness,
Current withstand
Meets all IEC/EN 61386-1, -23 standard requirements including:
• Impact resistance - Code 3 Medium; 6 Joules
• Tensile strength - Code 3 Medium; 500 N/2 min.
• Lower and upper temperatures
• IP protection against solid and liquids
Liquid-tight fittings for the most
demanding industrial and
commercial installations
Certifications / Standards:
1
—
TECHNICAL DATA SHEET
Steel & Malleable Iron fittings - Series 5200/5300
For liquid-tight flexible metallic conduit