T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Locknuts A (B) Thickness Steel or malleable iron (steel thru 2 in.) or Aluminum 624 Many of the T&B standard conduit and cable fittings are furnished with “case hardened locknuts”. This exclusive feature means the locknut tightens up against the box without deforming; the locknut bites into the box providing a positive ground; the fitting can be tightened from outside the box Stl. or M.I.
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Sealing Rings with Stainless Steel Retainer B A Sealing Ring-Santoprene Thermoplastic Rubber These sealing rings provide a liquid tight, dust tight, seal of fitting at enclosures Dimensions (in.) Cat. No. Conduit Size (in.
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Blackjack® — Conduit Grounding Bushings Mounting screw with nylon locking patch has a cone point to lock bushing securely in place Integral grounding lug enhances ground continuity. Added ground wire range taking reduces inventory.
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Blackjack® – Conduit Grounding Bushings Cat. No.
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Threaded Insulated Grounding Bushing Application Standard Material / Finish • For quick installation of bonding jumper to multiple metal conduits (Rigid and IMC) • Designed to bush conductors and prevent insulation damage Body: Electro-zinc plated Lay-in lug: Aluminum/tin-plated Insulator: Thermoplastic 150°C/302°F Application with 94V-0 flammability Features • Ease of installation, lay in lug design • Cast mal
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings A Insulated Throat Fittings B Nylon insulated metallic bushings Steel or malleable iron (Steel thru 1-1/2in.) The Canadian Electric Code 10-906 (2) calls for protetion of ungrounded conductors by means of smoothly rounded insulating surfaces at the entrance to raceways, pull boxes, junction boxes, etc.
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Insulating Bushing for Threadless Rigid Conduit and Intermediate Metal Conduit Application Standard Material • When assembled to the end of a threadless conduit, provides a well rounded insulating surface over which conductors may be pulled or on which conductors may bear while in service High impact thermoplastic listed for 105°C (221°F) application Flammability Classification 94V-1 Standard Finish As molded Features
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings 3210 Series C Application Standard Finish • To bush knockout openings in metal boxes or enclosures As molded Features • One piece construction designed to snap in place • High impact strength self-extinguishing, non-dripping (per UL 94) thermoplastic construction • 0.875 in. through 2.469 in. nominal diameter knockout opening (1/2 in. through 2 in.
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Knockout Plugs Application Range • To bush knockout openings in metal boxes or enclosures • 0.875 in. through 2.469 in. nominal diameter knockout opening (1/2 in. through 2 in. trade size knockouts) • Wall thickness of box or enclosure 0.095 in. max. up to 1 in. trade size 0.140 in. max. 1-1/4 in. through 2 in.
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Plug, Conduit, Connectors (Push-Penny® Plugs) Application Conformity • To plug open end of conduit or fitting in order to prevent ingress of trash, dirt or moisture during construction and remodeling CSA C22.2 No. 18 ANSI C80.
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Application • To effectively bush factory or field-punched, cut, or drilled holes in metal boxes or enclosures • To couple boxes back-to-back Features • Rugged construction • Insulator curled over to: Bush conductors entering/leaving at any angle. Reduce wire pull effort. Protect threads against damage in handling Standard Material 1942 Series Body 1/2in.-Steel 3/8 in., 3/4 in. through 6 in.
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Threaded Hubs (Bullet® Hubs) for Threaded Rigid Metal Conduit/IMC/PVC Coated Rigid Metal Conduit Application (A) Predetermined Compression (B) (C) (E) Features (D) 370 Series 370AL Series (G) (A) (F) (B) (G) (C) (E) (D) 485 Series B20 • To connect threaded metal conduit (ferrous rigid/nonferrous rigid/PVC coated/ or intermediate metal) to a threadless opening in a box or enclosure in outdoor or indoor location
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Threaded Hubs (Bullet® Hubs) for Threaded Rigid Metal Conduit/IMC/PVC Coated Rigid Metal Conduit (cont’d) Standard Material 370-485 Series Body Locknut Screws ‘O’ Ring Insulator Coating 370AL Series 1/2 in. thru 1 in. Steel 1-1/4 in. thru 6 in. Malleable Iron 1/2 in. thru 2 in. Steel (hardened) 2-1/2 in. thru 6 in. Malleable Iron Steel (hardened) Buna N Nylon PVC All Copper-Free Aluminum 1/2 in. thru 2 in.
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Steel/Malleable Iron and Aluminum Hub Fittings† Nylon insulated Aluminum, steel, or malleable iron (steel through 1 in.). With Neoprene “O” Ring provides a watertight threaded hub on enclosures. UL Listed 105°C. C A Cat. No. Stl. or M.I. 370 371 372 373 374 375 376 377 378 379-TB 381-TB 382-TB Alum.** 370AL 371AL 372AL 373AL 374AL 375AL — — — — — — A Dimensions (in.
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings PVC Coated Hub for Rigid Conduit Cat. No. NFS Thread C Dimensions (in.
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings The T&B® Hub Never before has a single hub fit like this one. Designed for unequalled performance. The innovative engineering of the T&B® Hub will, quite simply, raise your performance expectations for threaded hubs. The revolution in hub design is here, and the fate of our competition is sealed. 4 5 30º 1 3 2 6 Figure 1 1. Sealing ring and groove with innovative profile outperforms standard ’O’ ring design.
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings T&B Grounding Hub Dimensions (in.) Throat Dia. D E B C Cat. No. Zinc Cat. No. Aluminum H050GR-C H075GR-C H100GR-C H125GR-C H150GR-C H200GR-C H250GR-C H300GR-C H350GR-C H400GR-C H500GR-C H600GR-C H050GRA-C H075GRA-C H100GRA-C H125GRA-C H150GRA-C H200GRA-C H250GRA-C H300GRA-C H350GRA-C H400GRA-C H500GRA-C H600GRA-C Trade Size (in.) Dia. (in.) D Max. Panel Thickness E Throat Dia.
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings T&B Bulkhead Fittings Bulkhead Fitting Cat. No. Zinc H050BHD H075BHD H100BHD H125BHD H150BHD H200BHD H250BHD H300BHD H350BHD H400BHD H500BHD H600BHD Diameter TY PE 4 Across Flats Thread Cat. No. Aluminum H050BHDA H075BHDA H100BHDA H125BHDA H150BHDA H200BHDA H250BHDA H300BHDA H350BHDA H400BHDA H500BHDA H600BHDA Trade Size (in.
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings T&B XD Expansion/Deflection Coupling for Rigid Conduit Watertight, flexible connections support movement and thermal expansion Use the XD Expansion/Deflection Coupling to join two conduit runs in applications where movement in any direction is required. The coupling provides a flexible, watertight connection, accommodating axial or parallel movement of up to 3/4 in. and angular movement of up to 30˚ from normal position.
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings 4" Movement Shown T&B XJG Conduit Expansion Couplings for Rigid Conduit Internal Bonding Jumper Gland Nut Easy to Install — Save Time and Money on the Job No Disassembly Required! S 8" Movement Shown Bonding Bushing Packing Ring Teflon® (E.I.
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings T&B XJG-EMT Conduit Expansion Couplings for EMT Features • Fast and easy installation — no disassembly required • No external grounding strap needed — internal bonding jumper is protected from tampering and the environment Standard Material/Finish Body . . . . . . . . . . . . . . . Internal Bonding Jumper. . . . . Exterior and Interior Finish. . . . . . . . Packing. . . . . . . . . . . . .
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Offset Reducers Cat. No. Zinc Cat. No. Aluminum Trade Size (in.) Height (in.) Diameter (in.) A H150-075ORGR-TB H150-100ORGR-TB H150-125ORGR-TB H250-200ORGR-TB H150-075ORGRA-TB H150-100ORGRA-TB H150-125ORGRA-TB H250-200ORGRA-TB 1-1/2-3/4 1-21/32 2-3/4 15/16 Dimensions (in.
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Threadless Fittings/Couplings for Threadless Rigid Metal Conduit and Intermediate Metal Conduit Application Range • To connect and effectively bond threadless rigid metal conduit/intermediate metal conduit to a box or enclosure, or to couple ends of threadless conduit • 8123 & 8120 Series 1/2 in. through 4 in. Size Conduit • 8130 Series 1/2 in. and 3/4 in.
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Nylon Insulated Threadless Fittings B A C A split steel ring with diagonal serrations grips the conduit and bites into it for positive ground. Makes a permanent connection and eliminates the need for cutting a thread on the conduit. Insulation helps to guarantee continuity of service with protection of the conductor at the critical point — the fitting bushing. Cat. No. Nylon Insul.
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Specifications — Set-Screw Fitting/Coupling for Threadless Rigid Metal Conduit and Intermediate Metal Conduit Application • To connect and effectively bond threadless rigid metal conduit or intermediate metal conduit to a box or enclosure or to couple ends of threadless conduit Features 8125 Series • Thickwall steel or malleable iron body • Hardened hex head cup point screw to provide high quality bond • Captive sc
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Insulated Set-Screw Fitting Cat. No. B Dimensions (in.) Conduit Size (in.) 8125 8225 8325 8425 8525-TB 8625 8725-TB 8825 8855 8975 1/2 A B 1-3/8 13/32 3/4 1-1/2 7/16 1 1-13/16 35/65 1-1/4 2 5/8 1-1/2 2-5/16 5/8 11/16 2 2-7/16 2-1/2 3-3/8 1 3 3-7/16 1 3-1/2 3-7/8 1-1/16 4 4-3/16 1-1/8 Sizes 1/2 in.-2 in. made of steel. Sizes 2-1/2 in.-4 in.
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Bushed Elbows Cat. No. 460TB 461TB 462 463 B Size (in.) 1/2 A Dimensions (in.) B C 1-13/16 1-1/8 5/8 3/4 2-1/4 1-1/2 9/16 1 2-23/32 1-23/32 11/16 1-1/4 3-1/8 2-1/16 25/32 For Dura-Plate® finish, add prefix 040- to Cat. No.
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Threaded Couplings (ERICKSON®) Couplings for Threaded Rigid Metal Conduit and Intermediate Metal Conduit 675AL Series Bushing and Body Aluminum Ring Aluminum Application • To couple and effectively bond threaded ends of rigid metal conduit/intermediate metal conduit where neither length of conduit can be rotated Standard Finish 674 Series: Features • Malleable Iron/Steel/Copper-free Aluminum Construction • F
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Panel Fitting Extensions Cat. No. Size (in.) 1440 1441 1442 1443 C A 1/2 A Dimensions (in.) B C 1-1/4 1-3/16 1-7/8 3/4 1-1/4 1-13/32 1-15/16 1 1-3/16 1-21/32 1-15/16 1-1/4 1-1/4 2-1/8 2 A Dimensions (in.) B C 1-1/4 1-3/16 1-7/8 B Ideal when longer thread length is needed. Will combine with any fitting having a male thread. Male thread of panel fitting extension is 1 in. long.
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Threaded Reducers A For reducing the threaded opening in conduit bodies or any female threaded fitting. Smooth, built-in bushing completely covers rough ends of conduit. Iron or steel construction. Steel from 600-TB thru 606-TB, also 614 & 615. Cat. No. Stl. or M.I. 600-TB 601-TB 602-TB 603-TB 604-TB 605-TB 606-TB 607 608 609 610 611-TB 612 613 614-TB 615-TB Size (in) Alum.
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Conduit Straps for Threaded Rigid Metal Conduit and Intermediate Metal Conduit Application Standard Finish • To support and securely fasten rigid metal conduit and intermediate metal to the supporting surface 1275 Series Hot Dipped Galvanized 1276AL Series As Cast Features • Rugged malleable iron/copper-free aluminum construction—snugly fits on the conduit • Designed to prevent accumulation of moisture and start of
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Pipe Straps – Steel Cat. No. 1210C† 1211C 1212C 1213C 1214TB* 1215TB* 1216TB* C Conduit Size (in.) A Dimensions (in.) B C 3/8 1-15/32 3/4 11/16 1/2 2 3/4 15/16 3/4 2-5/16 3/4 1” 1-17/64 1 3-13/16 3/4 1-1/4 2-31/32 1-9/16 1-9/16 1-1/2 3-23/32 1-13/16 1-13/16 2 4-7/16 2-5/16 2-5/16 Screw Size (in.
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Conduit Spacers for Rigid Metal Conduit, Intermediate Metal Conduit and Electrical Metal Tubing Application Standard Finish • Provides mounting surface for conduit where installation requires air space between conduit and supporting surface 1350 Series Hot Dipped Galvanized 1350AL Series As Cast Features 1350 Series 1350AL Series • Prevents conduit rusting from wall condensation • Spacers can be stacked one atop t
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Pipe Spacers Cat. No. Mal. Iron 1350 1351 1352 1353 Dimensions (in.) A B Screw Size Size (in.) Alum. 1350AL 1351AL 1352AL 1353AL 3/8, 1/2, 3/4, 1 #7 3 7/8 1-1/4-1-1/2-2 #12 5 1-3/16 2-1/2-3 #12 9-9/16 1-3/4 3-1/2-4 #14 7-9/16 2 Conforms to CEC Rule 12-012 (5) UL not applicable A B Used with T&B conduit straps to permit space between conduit and mounting surface.
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Tite-Bite® Combination Couplings Armoured Cable for Threaded Rigid Cat. No. 440 441 442 B Size (in.) Dimensions (in.) A B 1/2 1-5/8 1-27/32 3/4 1-3/4 2-1/8 1 2 2-17/32 A A one-piece fitting that couples armoured cable or flexible conduit to threaded rigid conduit. Tite-Bite® wedge holds conduit securely with a double grip.
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Methods of Bonding and Grounding 1 1 1 CONCRETE TIGHT CONCRETE TIGHT RAIN TIGHT 2 3 Case 1: Where threaded or threadless conduit terminates into a threadless opening in a sheet metal box or enclosure with or without concentric or eccentric knockouts.
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Methods of Bonding and Grounding (cont’d) 1 1 1 CONCRETE TIGHT CONCRETE TIGHT RAIN TIGHT 2 3 Case 2: Where threaded or threadless conduit terminates into a threaded hub in a cast metal enclosure. 4 Methods of Bonding For Threaded hub in a cast metal enclosure w w w. t nb.
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Methods of Bonding and Grounding (cont’d) 1 2 1 Case 3: Where threaded conduit terminates into a threadless opening in a sheet metal box or enclosure with no concentric or eccentric rings remaining around knockout. 2 Threadless opening in a sheet metal box or enclosure 2 3 3 Method of bonding for 120/208 volt or 120/240 volts circuits (other than service equipment).
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Methods of Bonding and Grounding (cont’d) 1 1 5 1 2 2 5 6 OR w w w. t nb.
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Methods of Bonding and Grounding (cont’d) 5 3 Case 4: Where threaded conduit terminates into a threadless opening in a sheet metal box or enclosure with concentric or eccentric rings remaining around knockout. Methods of bonding for under or over 250-volts, for service equipment and for hazardous locations where applicable.
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Methods of Bonding and Grounding (cont’d) Bonding Service Equipment (CEC Rule 10-604) Install Bonding Jumper to Assure Electrical Continuity Between Isolated Sections of Raceways (CEC Rule 10-614) 1 Service conduit (Threaded rigid metal conduit or intermediate metal conduit) Threaded rigid metal conduit or intermediate metal conduit Service equipment enclosure Bonding required by CEC Rule 10-604 Bonding Method per CEC Ru
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Methods of Bonding and Grounding (cont’d) 2 Service Raceway (Rigid Metal Conduit or intermediate metal conduit) 1 Suitable for Bonding Raceway, EMT or Terminating Fitting to a sheet metal box or enclosure where 3 Grounding electrode Conductor Service enclosure with no unpunched rings around knockout 3 1 2 Ground Bus Grounding electrode Conductor Enclosure (1) (2) (3) B50 T&B Series 142 Locknut T&B Series 106 Bonding L
T&B ® Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Methods of Bonding and Grounding (cont’d) T&B Series 3651 Bonding & Grounding Wedge Acceptable Method for Bonding Following (i) Service Equipment CEC Rule 10-614 (ii) Bonding for Circuits over 250 volts CEC Rule 10-614 (iii) Bonding in Hazardous Locations CEC Rule 18-074 4 When installed with a bonding jumper, acceptable method of bonding where unpunched rings remain around concentric or eccentric knockouts in sheet