MSDS

49821
page 3 of 4
PROTECTIVE GLOVES
Wear gloves which are recommended by glove supplier for protection against materials in Section 2.
EYE PROTECTION
Wear safety spectacles with unperforated sideshields.
OTHER PRECAUTIONS
Intentional misuse by deliberately concentrating and inhaling the contents can be harmful or fatal.
SECTION 9 — PHYSICAL AND CHEMICAL PROPERTIES
PRODUCT WEIGHT
7.72 lb/gal 924 g/l
SPECIFIC GRAVITY
0.93
BOILING POINT
282 - 395 °F 138 - 201 °C
MELTING POINT
Not Available
VOLATILE VOLUME
18%
EVAPORATION RATE
Slower than
ether
VAPOR DENSITY
Heavier than air
SOLUBILITY IN WATER
Not Available
VOLATILE ORGANIC COMPOUNDS (VOC Theoretical - As Packaged)
0.75 lb/gal 90 g/l Less Water and Federally Exempt Solvents
0.68 lb/gal 82 g/l Emitted VOC
SECTION 10 — STABILITY AND REACTIVITY
STABILITY — Stable
CONDITIONS TO AVOID
None known.
INCOMPATIBILITY
None known.
HAZARDOUS DECOMPOSITION PRODUCTS
By fire: Carbon Dioxide, Carbon Monoxide
HAZARDOUS POLYMERIZATION
Will not occur
SECTION 11 — TOXICOLOGICAL INFORMATION
CHRONIC HEALTH HAZARDS
Reports have associated repeated and prolonged overexposure to solvents with permanent brain and nervous system damage.
Cobalt and cobalt compounds are classified by IARC as possibly carcinogenic to humans (group 2B) based on experimental animal data,
however, there is inadequate evidence in humans for its carcinogenicity.
TOXICOLOGY DATA
CAS No. Ingredient Name
64742-88-7 Med. Aliphatic Hydrocarbon Solvent
LC50 RAT 4HR Not Available
LD50 RAT Not Available
64742-65-0 Heavy Paraffinic Oil
LC50 RAT 4HR Not Available
LD50 RAT Not Available
98-56-6 p-Chlorobenzotrifluoride
LC50 RAT 4HR Not Available
LD50 RAT Not Available
136-52-7 Cobalt 2-Ethylhexanoate
LC50 RAT 4HR Not Available
LD50 RAT Not Available
SECTION 12 — ECOLOGICAL INFORMATION
ECOTOXICOLOGICAL INFORMATION
No data available.
SECTION 13 — DISPOSAL CONSIDERATIONS
WASTE DISPOSAL METHOD
Waste from this product may be hazardous as defined under the Resource Conservation and Recovery Act (RCRA) 40 CFR 261.
Waste must be tested for ignitability to determine the applicable EPA hazardous waste numbers.
Incinerate in approved facility. Do not incinerate closed container. Dispose of in accordance with Federal, State/Provincial, and Local
regulations regarding pollution.