Data Sheet

MKP336 2 X2
www.vishay.com
Vishay BCcomponents
Not for New Designs - Alternative Device: MKP339 X2
Revision: 25-Jul-2019
13
Document Number: 28120
For technical questions, contact: rfi@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
SUB GROUP C2
4.12.3 Final measurements Visual examination No visible damage
Legible marking
Capacitance |C/C| 5 % of the value measured in 4.12.1.
Tangent of loss angle Increase of tan :
0.008 for: C 1 µF or
0.005 for: C > 1 µF
Compared to values measured in 4.12.1.
Voltage proof
1350 V
DC
; 1 min between terminations
No permanent breakdown or flash-over
Insulation resistance 50 % of values specified in section “Insulation
resistance” of this specification
SUB-GROUP C3
4.13.1 Initial measurements Capacitance
Tangent of loss angle:
For C 1 µF at 10 kHz
For C > 1 µF at 1 kHz
4.13 Impulse voltage 3 successive impulses, full wave, peak voltage:
2.5 kV for C 1 µF
2.5 kV/C for C > 1 µF
Max. 24 pulses
No selfhealing breakdowns or flashover
4.14 Endurance Duration: 1000 h
1.25 x U
RAC
at 110 °C
Once in every hour the voltage is increased to
1000 V
RMS
for 0.1 s via resistor of 47 ± 5 %
4.14.7 Final measurements Visual examination No visible damage
Legible marking
Capacitance |C/C| 10 % compared to values measured in
4.13.1.
Tangent of loss angle Increase of tan :
0.008 for: C 1 µF or
0.005 for: C > 1 µF
Compared to values measured in 4.13.1.
Voltage proof
1350 V
DC
; 1 min between terminations
2120 V
AC
; 1 min between terminations
and case
No permanent breakdown or flash-over
Insulation resistance 50 % of values specified in section “Insulation
resistance” of this specification
SUB-GROUP C4
4.15 Charge and discharge 10 000 cycles
Charged to 435 V
DC
Discharge resistance:
GROUP C INSPECTION REQUIREMENTS
SUB-CLAUSE NUMBER AND TEST CONDITIONS PERFORMANCE REQUIREMENTS
R
435 V
DC
1.25 x C dU/dt
------------------------------------------------
=