User's Manual Part 1

Specifications - 18 -
®
Affinity LBD-200C-N1 Transmitter
Product Manual
Nominal Input Power, Average -18dBm
188 Thermal power sensor is
recommended to verify
average input power. Or PSD
method
2. UHF waveform COFDM DVB-H
Input Power variation
All conditions
r 3 dB from nominal input power
IF input Survivable Power,
NO DAMAGE
10 dBm
AGC and ALC on; input level at 0dBm
Spectral Mask of the input signal
Exceed FCC spectral mask definition
for the 1670-1675MHz band
Input Return Loss 10dB Measure at the IF input connector
Input Impedance
50 :
UHF Input Connector BNC-female
Parameter Specification Notes / Test Conditions
Front Panel Alarms/Indicators/Adjustments/Controls
Front panel display, System
forward output power
Relative output power (%) calibrated
against absolute output power (dBm)
Max. error 0.2 dB within 1.5 dB
window from nominal output power;
LCD display
Front panel display, reflected
output power
Relative reverse power (%) calibrated
against absolute output power (dBm)
100% at TX set to nominal output
power and SHORTED output (N
connector)
0% at nominal output power and 50
Ohm (16 dB return loss) load at the
transmitter output (N connector); LCD
display
Front panel display, upconverter
forward output power
Relative output power (%) calibrated
against absolute output power (dBm)
Max. error 1.0 dB within 1.5 dB
window from nominal output power;
LCD display
Front panel Diagnostics
LCD Displays with menu keys
LED display for power supplies
Module Control Interface
RS232 serial communications
protocol
Interface Connector
Front Panel RS232 port(s)
TNET Thales proprietary
RJ11 connector
Connector located on each plug-in
front panel
Parameters defined in plug-in level
specs
Refer to document # 47267228-306
Upconverter plug-in spec
Refer to document # 47266099.00-
306 Power Supply plug-in spec
Rear Panel Diagnostics Interface
Electrical Interface
Logic 0 for fault signals, 12V at 100mA,
Reset and stand-by Amplifiers
Diagnostics Interface connector Terminal block J1 connector of rear panel