Input liquid temperature fault
An "input liquid temperature" fault signal from the sensor in the internal cooling system sends a
command to lower the transmitter power by 6 dB.
SWR or amplifier overdrive fault
When the number of faulty amplifiers (SWR or overdrive fault) in the amplifier channel is greater than a
particular number (which depends on the total number of amplifiers), the fault processing system
triggers the following sequence of operations:
re-initialisation of the faulty amplifiers,
if the fault persists:
reduction of transmitter power by 3 dB,
re-initialisation of faulty amplifiers.
if the fault persists:
reduction of transmitter power by 6 dB,
re-initialisation of faulty amplifiers,
if the fault persists: shutdown of transmitter
SWR antenna fault
When the return wave antenna is higher or equal at 2, the fault processing system triggers the
following sequence of operations:
reduction of transmitter power by 3dB.
if the fault persists: reduction of transmitter power by 6 dB
if the fault persists: shutdown of transmitter.
Automatic exciter changeover (only applies to the dual drive version)
The fault processing system sends a changeover to reserve exciter command signal to the command
control system when one of the following fault signals is received and when the reserve exciter is
switched off and fault-free:
Exciter fault :
Communication link failure with the Sirius,
Power supply of exciter fault,
RF output signal missing from Sirius (Sirius rack is ON with an modulator not mute).
Modulator fault,
Sirius fault,
RF preamplifier fault,
Signal missing of the 10 MHz external (external GPS configuration only),
Board fault (synthetizer or TS board or Tx board or GPS board (internal GPS configuration only)
or EXT INPUT board (if installed card).
Pilot fault :
Signal missing of the 10 MHz external when the synthesizer 10 MHz is configured in external.
1 PPS signal missing when MUTE function is selected for this signal (in mode SFN only).
Absence or input MPEG-2 signal faulty when the modulator is not configured in PRBS (this
configuration is not possible in SFN mode).