CENTRAL PROCESSING UNIT (CPU)
POLLING OF
EVENTS DATA
Local control panel
Display
card
RF signal status
Call-up request
for type A
windows
Data base for
window display
Update
Data base for
window display
Screen
locked
Transmitter commands
Remote
control
mode
Local
control
mode
Operator commands
Operator commands
Call-up request for
type B windows
Update of window
DISPLAY
MANAGEMENT
Update of data base + type B window
Local control mode
Screen unlocked
Reserve exciter on*
Manual exciter changeover
Manual on-air command
Changeover performed
Maintenance mode
PCL INDICATOR
LAMPS CONTROL
SYSTEM
"Go home"indicator lit
Call-up
request for
type B
windows
CONTROL SYSTEM
FOR HARDWIRED
CONNECTIONS
REMOTE
USER
INTERFCE
(hardwired
connection)
Status data
Command data
DISPLAY CONTROL SYSTEM
* Only applies to the DD version
POLLING OF
OPERATOR
COMMANDS
Transmitter off-air
"On" indicator lit
RF power not correct
"Off" indicator lit
Local control mode
Screen unlocked
"Unlock" indicator lit
Exciter changeover
impossible
Buzzer
Transmitter on-air
Voyant "marche" allumé
1
Screen
unlocked
COMMAND
CONTROL
SYSTEM
RF probes
Call-up
request for
data
Data base
Update
Remote user
interface
98/240c(e)
Exciter input : PRBS
Incoherent DAP
Figure 7 : Block diagram of PCL windows and indicator lamps control system