2.1.2.5. "ETHERNET INSTALLATION PARAMETERS" window
This window appears when the changeover switch SW1 or S9 is switched so that the dot is visible and
It is called up by pressing the "INSTALL NEXT" control keys in "INSTALLATION EXCITER
PARAMETERS" window.
This window is used to change the Ethernet configuration parameters used by the communication
network. It is only available with TH860 CPU Board.
that CPU board is reset.
For Digital Transmitter
It is called up by pressing the "INSTALL NEXT" control keys in "INSTALLATION ADAPTATION
PARAMETERS" window.
For Analogue Transmitter
MESSAGE & CONTROL KEYS FUNCTIONS SELECTIONS AVAILABLE/COMMENTS
Displays the identification number of
the CPU board
This reference is single and associated to one
CPU board
Used to insert the WEB activation
code.
Displays the WEB activation code,
without option in operation the
control keys displays: “0”
THALES produces activation code of the
“Agent WEB” option. This code is single and
associated to the identification number of the
CPU board
Pressing this key calls up the "NUMERICAL
VALUE" window in which this code value can
be inserted.
Used to insert the SNMP activation
code.
Displays the SNMP activation code,
without option in operation the
control keys displays: “0”
THALES produces activation code of the
“Agent SNMP” option. This code is single and
associated to the identification number of the
CPU board
Pressing this key calls up the "NUMERICAL
VALUE" window in which this code value can
be inserted.
Used to Insert the IP address of the
transmitter in an Ethernet network.
Displays the IP address in operation.
When the Ethernet network is not
operated the control keys must
display: “0.0.0.0”
Your network administrator gives the IP
address.
NOTA : IP wrong address disturbs the
network.
Calls up the "NUMERICAL VALUE" window
9932 V2
45321648.01 108 B E
Checked
51 / 192
Numéro / Number Doc. Rev. Lan
g
u.
27/06/2006
Pa
g
e