CONTROL KEYS FUNCTIONS SELECTIONS
AVAILABLE/COMMENTS
Selects the delay value.
Mod Dly : The number of clock
cycles corresponding to the delay
through the FLO modulator core.
This is set to align the start of
superframe at the RF output to the
GPS 1PPS.
TX Dly : This value is the latency
associated with the transmit
hardware. It’s used to compensate
for the transmit delay in order to
synchronize transmissions from
multiple sites in an SFN network.
Ntw Dly: This value is the latency
associated with the geographic
separation of transmitters. It’s used
to synchronize transmissions from
multiple sites in an SFN network.
SFN lim: If the absolute value of the
system clock integrity count is
greater than this limit, it is out of
range and an alarm generated.
Pressing this key calls up the
"NUMERICAL VALUE" window in which
this value can be changed.
Cancels a selection.
Validates a selection.
Calls up the "FLO 2 MODULATOR
PARAMETERS" window.
Calls up the "STATUS" window.
Calls up the "CONTROL MAINT Level 2"
window.
Calls up the "EXCITER Level 1" window.
Calls up the "AMPLIFIERS" window.
Calls up the «INTERLOCK» window
Calls up the "POWER SUPPLY" window.
9932 V2