Use and Care Manual
Gas Supply Requirement
40
11. Gas Supply Requirement
Installation of this range must conform with local codes, or in the absence of local codes, with national
Fuel Gas Code,ANSIZ223.1 / NFPA 54. In Canada, installation must conform to the current natural Gas
Installation /code, CAN 1-1.1-M81 and with local codes where applicable. This range has been design-
certified according to ANSIZ21.1a, latest edition.
LP Gas
in.w.c.
Natural Gas
in.w.c.
Maximum gas supply pressure
13.0
10.0
Appliance regular is set at
10.0
5.0
Keep appliance area clear and free from combustible materials, gasoline, and other flammable vapors.
Do not obstruct the flow of combustion air into the range and ventilation air away from the range.
Ventilation: it is a must that the unit be set under a powered, vented exhaust hood of sufficient size and capacity.
Before installing the range, you must locate and secure the included anti-tip bracket to the wall for your range.
The use of cabinets for storage above the appliance may result in a potential burn hazard. Combustible items may
ignite; metallic items may become hot and cause burns. If a cabinet storage is to be provided, the risk can be
reduced by installing a range hood that projects horizontally a minimum of 5" (12.7cm) beyond the bottom of the
cabinets.
Connect Range to Gas Supply
1. Install a manual gas line shut-off valve in the gas line in an easily accessed location outside the
range in the gas piping external to the appliance for the purpose of turning on or shutting off gas
to the appliance.
Install male ½-inch flare union adapter to ½-inch NPT internal thread elbow at inlet of regulator. On
models equipped with standard twin burners, install the male pipe thread end of the ½-inch flare
union adapter to the ½-inch NPT internal thread at inlet of pressure regulator. Use a wrench on the
regulator fitting to avoid damage.
2. Install male ½-inch or
3
/
4
-inch (not on HRD dual fuel range) flare union adapter to the NPT
internal thread of the manual shut-off valve, taking care to secure the shut-off valve to keep it
from turning.
3. The gas supply pressure for checking the regulator setting is 6 in.w.c. (Nature Gas) and 11 inch.w.c.
(LP gas) connect flexible gas line connector to the regulator on the range. Position range to permit