Use and Care Manual
Gas Supply Requirement
41
connection at the shut-off valve.
4. When all connections have been made, make sure all range controls are in the position and
turn on main gas supply valve.
5. Leak testing of the appliance shall be conducted according to the manufacture’s instructions. Use
some soap water (50% water and 50% soap) or a leak detector at all joints and connections to
check for leaks in the system. Do not use a flame to check for gas leaks.
6. 6.The appliance must be isolated from the building’s gas supply piping system by closing its
individual manual shut-off valve during any pressure testing of the gas supply piping system at
test pressure equal to or less than
1
/
2
psig(3.5kPa).
After installation:
1. Check ignition of cooktop burners.
2. Check ignition of oven burner.
3. Visually check tubular burner (oven burner) re-ignition to be sure both rows of burner ports are
relighting each time.
4. Check for gas leaks at all gas connections ( using a gas detector, never a flame).
5. Check oven bake, and convection bake function.