Dimensions Guide

Thor Kitchen Gas Rangetops
16
TROUBLESHOOTING TIPS
Possible Cause
Solution
Burner parts or igniters may be
wet, dirty or misaligned.
Check that the burner parts are
clean, dry and correctly assembled.
Check that the igniters are clean
and dry.
Failed thermocouple
Replace thermocouple
Burner parts may be dirty or
misaligned.
See “Care and Cleaning”
instructions.
Burner bezel ports are clogged.
Burner ports or burner caps are
not positioned properly.
Range top is being operated with
the wrong type of gas.
Regulator is not Installed, is
faulty, or is set for the wrong
type of gas.
Clean burner bezel ring ports with
straightened paper clip, needle, or
wire.
Remove and carefully re-install
burner bezel and caps.
Ensure that the type of range top
matches the gas supply.
Check installation, replace
regulator, or set regulator for
proper gas.
Gas shut-off valve is in the “OFF”
position.
Turn shut-off valve to the “ON”
position.