User Manual

Thor Kitchen Gas Rangetops
7
The installation of range tops designed for recreational vehicle installation must conform with state or
other codes or, in the absence of such codes, with the
standard for recreational vehicles. ANSI A119.2.2–1982 in the U.S.A. or CAN/CGA
Z240.4.2 in Canada.
The installation of appliances designed for recreational park trailers must conform with state or other
codes or, in the absence of such codes, with the standard for recreational park trailers, ANSI A119.5.
Note: Check all piping connections in the unit for leaks. Never use an open flame to check for gas leaks.
Use a soap solution, 75% water, 25% dish washing soap. It is possible for connections made at the
factory to leak, due to vibration encountered in transportation. Make certain you have checked them
all, and repair any connections that leak.
The appliance and its individual shut-off valve must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures in excess of 1/2 psig.
The appliance must be isolated from the gas supply piping system by closing its individual manual shut-
off valve during any pressure testing of the gas supply piping system at test pressures equal to or less
than 1/2 psig.
GAS LINE SHUT-OFF VALVE
To reduce the possibility of gas leaks, apply Teflon tape or a thread compound approved for use
with LP or Natural gases to all threaded connections.
Install a manual gas line shut-off valve in the gas line in an easily accessed location outside the
range in the gas piping external to the appliance for the purpose of turning on or shutting off gas to
the appliance.
Install male 1/2’’(30 or 36 inch rangetop) or 3/4” (48 inch range top) flare union adapter to 1/2” or
3/4’’ NPT internal thread elbow at inlet of regulator. Use a wrench on the regulator fitting to avoid
damage.
Install male 1/2” or 3/4” flare union adapter to the NPT internal thread of the manual shut-off valve,
taking care to secure the shut-off valve to keep it from turning.
Check for leaks using a leak detector or soapy water, 75% water, 25% dish washing soap.
INSTALLATION / CLEARANCES
All units must be installed in accordance to minimum rear and side wall clearances and clearances
extended vertically above cooking top which are stated on the serial plate (the serial plate is located on
the back of the unit.)
Make sure that the wall coverings, counter tops and cabinets around the range top can withstand
temperatures of up to 200 ˚F/93 ˚C generated by the range top.
It is the responsibility of the installer to make certain that the range top is properly adjusted at the
time of installation. Situations caused by improper adjustments or improper installation are not
covered under the warranty. Any expenses incurred due to such situations will not be paid by the
manufacturer of the appliance.