Operating Guide

Instructions for Converting Range to Operate on Liquefied Petroleum Gas
INSTALLATION AND SERVICES MUST BE PERFORMED BY A QUALIFIED INSTALLER
IMPORTANT: SAVE INSTRUCTION MANUAL FOR THE LOCAL INSPECTOR’S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
Determine the combination of top burners that are featured on your range. Identify the parts you need from this
kit to complete the L.P. conversion. When burners are converted from natural to L.P. the BTU ratings are as
follows: Note: For operation at elevations above 2000ft., appliance rating shall be reduced at the rate of 4% for
each 1000 ft. above sea level.
*LP Joint Compound (Pipe Dope) is needed for All LP Orifices installation, or a Potential Gas Leak might occur.
Top (from Left to Right): Orifice for Oven Burner / Oven Broiler Burner
Middle: 18,000 BTU Top Burner Orifice (2 pcs)
Bottom (from Left to Right): 12,000 BTU Top Burner Orifice (2 pcs), 9,000 BTU Top Burner Orifice (2 pcs)
Top Burner
Simmer
burner
Griddle
Burner
Oven Burner
Broil Burner
Bypass
Jet
18000
12000
9000
18500
10000
Orifice
Size(mm)
1.24
1.00
0.88
1.12
0.9
LRG3601U
2
2
2
NA
NA
NA
NA
1
NA
1
NA
0
This conversion kit must be installed by a qualified service technician in accordance with the
manufacturer's instructions and all applicable codes and requirements of the authority having jurisdiction.
Failure to follow instructions may result in fire, explosion or production of carbon monoxide causing property
damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation
of this kit. The installation is not proper and complete until the operation of the converted appliance is
checked as specified in the manufacturer's instructions supplied with this kit.
Before proceeding with the conversion, shut off the gas supply before disconnecting
electrical power to the range. Be sure power supplies are off before installing the conversion kit. Failure to
do so could cause serious bodily injury.