Use and Care Manual

Instructions for Converting Range to Operate on Liquefied Petroleum Gas
IMPORTANT: After replacing the natural gas to LP orifices, be sure to keep the original factory installed natural gas
orifices for future range conversion back to natural gas.
Tools for LP Conversion
7mm Tool Top Burner Orifice Replacement
Flat Screw Driver 2.0*130 (Not Available with the LP Conversion Kit Package) Bypass Adjustment
Adjustable Wrench *2 (Not Available with the LP Conversion Kit Package) Orifice Adjustment
LRG3601U LP Conversion
1. Convert the Pressure Regulator
Locate the regulator on the back left of the range’s back panel.
**IMPORTANT** Be aware that there’s a difference on regulator cap position between NG and LP. All the gas
ranges are initially manufactured with regulator cap on NG position, please reverse the cap for LP conversion.