Manual Spec Sheet

Troubleshooting
If you encounter a problem with the cooktop, check the tables starting
below, and then try the suggested actions.
Checkpoints
Gas Cooktop Conversion
The cooktop is set for use with Natural Gas (NG).The factory setting
is indicated on the serial plate.When set for Natural Gas(NG) operation,
the pressure regulator will regulate the gas to 4” inches water column
pressure.When set for Liquefied Propane Gas(LPG)operation,the
pressure regulator will regulate the pressure to 11”inches water column.
Please refer to Instructions for Converting cooktop to Operate on
Liquefied Petroleum Gas.
Gas safety
Determine the combination of top burners that are featured on your
cooktop. Identify the parts you need from this kit to complete the L.P.
conversion. When burners are converted from natural to L.P. the BTU
ratings are as follows: Note: For operation at elevations above 2000ft.,
appliance rating shall be reduced at the rate of 4% for each 1000 ft.
above sea level.
NG to LPG Conversion
Convertible Pressure Regulator
The cooktops are shipped to operate on Natural Gas (NG). Save
the NG orifices removed from the appliance for future use,make
sure you note which orifices are for which burner if you plan on
converting back to NG.
Instructions for Converting cooktop to Operate on Liquefied
Petroleum Gas
INSTALLATION AND SERVICES MUST BE PERFORMED
BY A QUALIFIED INSTALLER
IMPORTANT: SAVE INSTRUCTION MANUAL FOR THE LOCAL
INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE
- 23-
- 24-
NG
1.88mm
1.50mm
1.30mm
1.30mm
LPG
1.24mm
1.00 mm
0.90 mm
0.90mm
TGC3601
Left Front
Left Rear
Right Front
Right Rear
Center Front
Center Rear
NG
1.88 mm
1.50 mm
1.06 mm
1.06 mm
1.88 mm
1.50 mm
LPG
1.24 mm
1.00 mm
0.70 mm
0.70mm
1.24 mm
1.00 mm
Problem
Possible cause
Action
You smell gas.
The surface burner knob is not in the
OFF position and the burner is not lit.
Turn the burner knob to OFF.
There is a gas leak.
Clear the room, building, or area of all occupants.Immediately call your gas
supplier from a neighbor’s phone. Do not call from your phone. It is electrical and
could cause a spark that could ignite the gas. Follow the gas supplier’s
instructions.If you cannot reach your gas supplier, call the fire department.
Surface
burners do
not light.
The control knob is not set properly.
Push in the control knob and turn it to the Lite position.
The burner caps are not in place.
The burner base is misaligned.
Clean the electrodes. Put the burner cap on the burner head.Align the
burner base.
A surface burner
clicks during
operation.
The control knob has been left in the
Lite position.
After the burner lights, turn the control knob to a desired setting.If the
burner still clicks, contact a service technician.
Very large
or yellow surface
burner flames.
The wrong burner orifice is installed.
Check the burner orifice size. Contact your installer if you have the wrong
orifice (LP gas instead of natural gas or natural gas instead of LP gas).
!
WARNING
This conversion kit must be installed by a qualified service technician in accordance
with the manufacturer's instructions and all applicable codes and requirements of the authority having
jurisdiction. Failure to follow instructions may result in fire, explosion or production of carbon monoxide
causing property damage, personal injury or loss of life. The qualified service agency is responsible
for the proper installation of this kit. The installation is not proper and complete until the operation of
the converted appliance is checked as specified in the manufacturer's instructions supplied with this kit.
!
WARNING
Before proceeding with the conversion, shut off the gas supply before disconnecting
electrical power to the range. Be sure power supplies are off before installing the conversion kit.
Failure to do so could cause serious bodily injury.