TROUBLESHOOTING
2. Convert Burner for LP/ Propane Gas
Save the natural gas orifices removed from the appliance for possible future conversions to
natural gas. You should rely on the following process when converting unit back to Nature gas.
Take extra care when handling orifice parts, making sure the orifice is not
a. Remove top grates, burner caps and inner burner rings.
b. Lift off outer burner heads and burner bases.
c. Remove the factory installed natural gas orifices from the center of the orifice holders using
a 7mm nut driver Remember to keep the original natural gas orifices for future conversions
back to natural gas.
“IMPORTANT”to identify their markings.
c.1. Replace the 18000BTU burner orifice in each with orifice size 1.24 mm. c.2 Replace the
12000BTU burner orifice in each with orifice size 1.00 mm. Please remember not to over
tighten the orifice and keep the orifice clean. c.3 Replace the 9000BTU burner orifice in each
with orifice size 0.90 mm. Please remember not to over tighten the orifice and keep the orifice
clean. c.4 Replace the 6000BTU burner orifice in each with orifice size 0.70 mm. Please
remember not to over tighten the orifice and keep the orifice clean. Put the burner flame ring
back to the main burner bases. Put back the inner burner rings, burner caps and grates.
25