Warranty

-25- -26-
Left Front
Right Front
Right Rear
Left Rear
TGC3001
BURNER PERFORMANCE
Total number of cooktop Burners
4Burners
18000 BTU/H
12000 BTU/H
9000 BTU/H
9000 BTU/H
TGC3601
BURNER PERFORMANCE
Total number of cooktop Burners
6Burners
Center Front
Left Front
Left Rear
Center Rear
Right Front
Right Rear
18000 BTU/H
12000 BTU/H
18000 BTU/H
12000 BTU/H
6000 BTU/H
6000 BTU/H
IMPORTANT: After replacing the natural gas to LP orifices, be sure to
keep the original factory installed natural gas orifices for future range
conversion
back to natural gas.
Tools for LP Conversion
7mm Tool – Top Burner Orifice Replacement
Flat Screw Driver 2.0*130 (Not Available with the LP Conversion Kit
Package)
Bypass Adjustment Adjustable
Wrench *2 (Not Available with the LP Conversion Kit Package) – Orifice
Adjustment
TGC3001&TGC3601 LP Conversion
1.Convert the Pressure Regulator
For 30 or 36-inch Cooktop, you could find your regulator on the back left of
the cooktop's back panel.
**IMPORTANT** Pay attention that the NG and LP are in different
direction. All the cooktop are initially designed with NG position, please
have it changed in to LP position.
2.Convert Burner for LP/ Propane Gas
Save the natural gas orifices removed from the appliance for possible
future conversions to natural gas. You should rely on the following
process when converting unit back to Nature gas. Take extra care
when handling orifice parts, making sure the orifice is not
a. Remove top grates, burner caps and inner burner rings.
b. Lift off outer burner heads and burner bases.
c. Remove the factory installed natural gas orifices from the center
of the orifice holders using a 7mm nut driver Remember to keep
the original natural gas orifices for future conversions back to
natural gas.
IMPORTANTto identify their markings.
c.1. Replace the 18000BTU burner orifice in each with orifice size 1.24 mm.
c.2 Replace the 12000BTU burner orifice in each with orifice size 1.00 mm.
Please remember not to over tighten the orifice and keep the orifice clean.
c.3 Replace the 9000BTU burner orifice in each with orifice size 0.84 mm.
Please remember not to over tighten the orifice and keep the orifice clean.
c.4 Replace the 6000BTU burner orifice in each with orifice size 0.75 mm.
Please remember not to over tighten the orifice and keep the orifice clean.
Put the burner flame ring back to the main burner bases. Put back the inner
burner rings, burner caps and grates.