Table Of Contents
Chapter 2: To get started
98-148232-B Fixed installation of the EXPLORER 540 10
2. Insert the positive wire into the terminal marked 1-DCIN+ in the DC terminal block and
tighten the screw.
3. Insert the negative wire into the terminal marked 2-DCIN- in the DC terminal block and
tighten the screw.
4. If the DC cable is shielded, insert the end of the shield into the terminal marked 3-GND in
the DC terminal block and tighten the screw.
5. Tighten the cable gland.
Fixed installation of the EXPLORER 540
To install the EXPLORER 540 in a fixed installation, use the pole mount kit included in the
delivery.
For details on how to install the EXPLORER 540, see the included installation guide.
To power the EXPLORER 540
The EXPLORER 540 has no power switch, but is automatically switched on when power is
applied to the DC input or the LAN interface.
Use one of the following power sources (connected at installation, see the Installation guide):
PoE+ via the LAN interface
12 or 24 VDC nominal, e.g. from a battery (absolute maximum rating 10.5-32 VDC)
Important
Make sure all cables are connected and the Installation process for satellite
operation is completed before you fasten the EXPLORER 540 in your fixed
installation.