User Manual

Table Of Contents
Chapter 3: Operation
98-148232-B To access the terminal from a remote location 23
WATCHDOG: Request or modify watchdog settings
The text in the WATCHDOG SMS must have the following format:
WATCHDOG
<wdog_op> <ping1> <ping2> <ping3> <ping_ always> <ping_ interval> <wdog_
enable> <rsms_pwd>
Example: WATCHDOG 2 100.100.100.130 100.100.100.110 200.247.237.254 0 20 1
remote
In this example, Link monitoring is set up as follows:
2: Set watchdog parameters
100.100.100.130: Primary IP address
100.100.100.110: Secondary IP address
200.247.237.254: Tertiary IP address
0: Send ping only if no IP data traffic
20: Ping interval (number of minutes between pings)
1: Enable watchdog
remote: Remote SMS password
Response:
You do not get an OK response. You can use the WATCHDOG 1 command to get the status of
the WATCHDOG feature.
See also Link monitoring (watchdog) on page 29.
ADPWRST: Reset the administrator password
To reset the administrator password you need the IMEI number of your terminal. If you can
access the web interface, you can find the IMEI number under Support > Extended status,
see To view extended status on page 60.
The text in the ADPWRST SMS must have the following format:
ADPWRST 1 <imei> <rsms_pwd>
Example: To reset the administrator password of a terminal with the IMEI number 363833-
09-012345. send an SMS with the text:
ADPWRST 1 36383309012345 remote
Response:
You receive a response with the result of the action.
Example: A response for a successful ADPWRST command, could be:
ADMIN RESET SUCCESS
SMS-Free: 88/100
WARNING: Ensure SMS-free > 5. Cleanup old msgs for
orderly Remote SMS Control