User Manual
Table Of Contents
- Safety summary
- Antenna safety instructions
- About this manual
- Introduction to EXPLORER 540
- To get started
- Operation
- Configuration with web interface
- The web interface
- To control data connections from web interface
- To set up your data connection packages (BGAN M2M)
- Status information
- The Control panel
- To restart the installation process
- To use the logs
- Terminal settings
- Port forwarding
- To manage connected devices (Traffic control)
- To set up tracking
- Support features
- Advanced settings
- To enter the SIM PIN in the web interface
- Maintenance and troubleshooting
- Technical specifications
- Command reference
- BGAN non-M2M functions
- Conformity
- Glossary
- Index
Chapter 4: Configuration with web interface
98-148232-B To restart the installation process 47
To restart the installation process
If you need to restart the installation process, e.g. because the EXPLORER 540 has been moved
to another location, click the Installation tile in the Control panel. This will reboot the
terminal and restart the installation process. For details about the installation process, see
Installation process on page 11.
To start the installation process from the web interface, do as follows:
1. Select
(Control panel) and then Installation.
2. Select OK to reboot the terminal and start the installation process. Note that you must log
into the web interface with user name and password after reboot.
The signal strength is shown on the screen during the pointing process.
3. Turn and tilt the antenna slowly until you have obtained the highest possible signal
strength. You can use the pointing sound as well as the signal strength shown on screen.
For details, see Installation process for satellite operation on page 12.
4. When the EXPLORER 540 has detected a stable BGAN signal it automatically exits the
pointing process and starts to connect to the BGAN network.
• If you do nothing, the EXPLORER 540 automatically connects to the BGAN network (if
possible) and then completes the installation process.
• If you want to cancel installation and start over at next power-up, click Cancel. You can
still configure the EXPLORER 540, and the LED will be active.
If there are problems with the installation, the web interface will show a warning icon next
to the failing step in the installation window. The LED on the EXPLORER 540 will be yellow
(warning). See Troubleshooting guide on page 78.
5. Tighten the screws to fix the EXPLORER 540 in the pointed position.
6. When the installation process has ended, click Close to close the Installation window.