User's Manual
Table Of Contents
- Safety summary
- Preface
- Training information
- About this manual
- Introduction
- Installation
- Interface description
- Configuration
- Service & maintenance
- Technical specifications
- NMEA sentences
- B.1 NMEA sentences used
- B.2 Sentence use reference
- B.2.1 ABK - AIS addressed and binary broadcast acknowledgement (output)
- B.2.2 ABM - AIS addressed binary and safety related message (input)
- B.2.3 ACA - AIS channel assignment message (input / output)
- B.2.4 ACK - Acknowledge alarm (input)
- B.2.5 AIR - AIS interrogation request (input)
- B.2.6 ALR - Set alarm state (output)
- B.2.7 BBM - AIS broadcast binary message (input)
- B.2.8 DTM - Datum reference (input)
- B.2.9 EPV - Command or report equipment property value (input / response output)
- B.2.10 GBS - GNSS satellite fault detection (input)
- B.2.11 GGA - Global positioning system (GPS) fix data (input)
- B.2.12 GNS - Fix data (input)
- B.2.13 HBT - Heartbeat supervision sentence (input)
- B.2.14 HDT - Heading true (input)
- B.2.15 LR1 - AIS long-range reply sentence 1 (output)
- B.2.16 LR2 - AIS long-range reply sentence 2 (output)
- B.2.17 LR3 - AIS long-range reply sentence 3 (output)
- B.2.18 LRF - AIS long-range function (input / output)
- B.2.19 LRI - AIS long-range interrogation (input / output)
- B.2.20 NAK - Negative acknowledgement (output)
- B.2.21 PTHRAOC - AIS operational control (input / output)
- B.2.22 PTHRROS - Radio operational status (output)
- B.2.23 RMC - Recommended minimum specific GNSS data (input)
- B.2.24 ROT - Rate of turn (input)
- B.2.25 SPW - Security password sentence (input)
- B.2.26 SSD - AIS ship static data (input / output)
- B.2.27 THS -True heading and status (input)
- B.2.28 TRL - AIS transmitter non functioning log (output)
- B.2.29 TXT - Text transmission (output)
- B.2.30 VBW - Dual ground/water speed (input)
- B.2.31 VDM - AIS VHF data-link message (output)
- B.2.32 VDO - AIS VHF data-link own-vessel report (output)
- B.2.33 VER - Version (output)
- B.2.34 VSD - AIS voyage static data (input / output)
- B.2.35 VTG - Course over ground and ground speed (input)
- B.2.36 ZDA - Time and Date (output)
- Supported keys
- Glossary
- Index
Physical installation of the SAILOR 6280 AIS System
98-137573-A Chapter 3: Installation 3-9
3333
Installation
Maximum wire cross section: 2.5 mm
If the SENSOR or PI is used for high speed communication (38400 baud) the related jumper
must be closed. Closing the jumper terminates the Rx A and Rx B lines with 120 Ohm.
Figure 3-7: Connectors of the SAILOR 6283 AIS Connection Box and Wall Tray
W8
W7
W6
W5
W4
W3
W2
W1
RV1
R7
R6
R5
R4
R3
R2
R1
J3
J2
J7
J5
J6
J8
J9
J10
J11
J1
ALARM
BLUESIGN
1W
NO
COM
NC
N
P
C
FUSED
-
SENSOR1
PI1
Rx A
Rx B
Rx C
Rx C
Rx B
Rx A
Tx C
Tx B
Tx A
PI2
AIS ON
POWER
DC
DC
ON_IN
ON_OUT
SENSOR2
PI3
Tx C
Tx B
Tx A
Rx C
Rx B
Rx A
Rx C
Rx B
Rx A
SENSOR3
PI4
+
+
-
Rx C
Rx B
Rx A
Tx C
Tx B
Tx A
Rx C
Rx B
Rx A
Tx C
Tx B
Tx A
Rx A
Rx B
Rx C
Jumper Description
W5 SENSOR 1
W3 SENSOR 2
W1 SENSOR 3
W2 PI1
W7 PI2
W6 PI3
W4 PI4
W8 Must always be closed to switch on the SAILOR 6282
AIS Transponder.
Table 3-2: Jumper settings on the SAILOR 6283 AIS Connection Box and
Wall Tray