User's Manual

Table Of Contents
Presentation Interfaces
98-137573-A Chapter 4: Interface description 4-7
4444
Interface description
4.3.2 Electrical Characteristics
The schematics for the presentation interfaces is shown in the following figure. The
presentation interfaces support both IEC61162-1 and IEC61162-2, i.e. baud rates from
4800 to 38400, input voltages down to 0.3 VDC and electrical isolation between each
sensor input and the internal power supply.
The load of each input is maximum 2 mA at minimum 2 VDC.
Each output can drive maximum 20 listeners, each consuming 2 mA.
4.3.3 Configuration of the Presentation Interfaces
All four presentation interfaces are IEC61162-1/2 (RS-422) compliant and can be
configured individually with different baud rates. From the factory the ports are setup with
the default baud rate as follows:
See Interface settings on page 5-12 to learn how to set up theSAILOR 6282 AIS
Transponder using the Service Interface.
Figure 4-4: Schematics of presentation interfaces
PI 1 TX B
PI 1 TX A
PI_1_TX
U29D
ISL32374E
Y4
14
Z4
13
DI4
15
BLM15AG102SN1
E21
BLM15AG102SN1
E22
Port ID Default baud rate Function
PI1 38400 ECDIS
PI4 4800 Long Range
PI2 38400 Pilot plug
PI3 38400 AUX
Table 4-4: Presentation interfaces – default baud rate