User's Manual

Table Of Contents
Alarms and notifications
6-6 Chapter 6: Service & maintenance 98-137573-A
Rx channel
AIS 2
malfunction
(ID 004)
The SAILOR
6282 AIS
Transponder
stops
transmitting on
the affected
channel.
If continuous monitoring
of the receiver channel 2
shows inconsistency, this
alarm is activated.
Check the VHF
antenna, plugs, and
cable to the AIS
Transponder.
Rx channel
70
malfunction
(ID 005)
The SAILOR
6282 AIS
Transponder
continues
operation, but
external channel
management is
not possible.
If continuous monitoring
of the receiver channels
shows inconsistency, this
alarm is activated.
Check the VHF
antenna, plugs, and
cable to the AIS
Transponder.
General
failure
(ID 006)
The SAILOR
6282 AIS
Transponder
stops
functioning. In
case of severe
software or
hardware failure,
this alarm is
activated.
Check the power
supply to the AIS
Transponder.
UTC sync
invalid
(ID 007)
The SAILOR
6282 AIS
Transponder
continues
operation using
indirect or
semaphore
synchronization.
If the internal GNSS
receiver cannot receive a
synchronization signal
from the satellites, this
alarm is activated.
Check the GNSS
antenna, plugs, and
cable to the AIS
Transponder.
Alarm Consequence Reason Remedy
Table 6-1: AIS Alarms (Continued)