Installation Manual

Prerequisites
3-4 Chapter 3: Installation 98-152675-A
Cobham Public
connector/skin penetration area. The gasket may have to be reduced in size to achieve this
and it will be different for different radii of aircraft fuselages.
If an injectable sealant is considered:
1. Apply sealant to the whole undersurface, EXCEPT the yellow areas, the O-ring and the
area inside the O-ring as indicated in Figure 3-2
2. Take care that NO SEALING is applied in the breathing/drainage slot areas indicated in
Figure 3-3. The breathing and drainage slots are also the air paths to allow breathing and
drainage of liquids penetrating the slots due to cleaning or de-icing of the aircraft.
Important
The sealing compound should have a low enough viscosity to be squeezed
out readily during fastening of the attachment bolts to ensure that the
antenna is seated as close to the fuselage skin as possible, i.e. the bonding
areas (feet) should be in contact with the fuselage skin.
Note
Note the requirements for provisions for grounding and bonding in section
3.4.3 (GB).
Figure 3-2: Areas where NO sealant is to be applied
Figure 3-3: Breathing/drainage slots, both sides
Mounting foot
GB
Mounting foot
GB
O-ring sealing area
GB