Installation Manual

DO-160 specifications
A-2 Appendix A: Equipment specifications 98-152675-A
Cobham Public
A.2 DO-160 specifications
A.2.1 Qualification Forms
The Environmental Qualification Forms list the environmental categories under which the
LGA-5005 has been approved.
Part Number:
LGA-5005
Qualification Details
Environmental Refer to RTCA DO-160G for further details on the
following Environmental Qualification Forms.
Table A-2: Qualification Forms
Conditions DO-160G Cat. Comments
Temperature and
Altitude
For installation in:
Non-controlled-temperature locations
Non-pressurized locations.
Pressurized locations.
Low temperature 4.5.1 & 4.5.2 F2 For installation in non-controlled-temperature
locations.
Ground Survival Low Temperature: -55°C
Short-Time Operating Low Temperature: -55°C
Operating Low Temperature: -55°C
High temperature 4.5.3 & 4.5.4 F2 For installation in non-controlled-temperature
locations.
Ground Survival High Temperature: +85°C
Short-Time Operating High Temperature: +70°C
Operating High Temperature: +70°C
The antenna will disable its transmitter when needed to
prevent damage due to overheating.
In-flight loss of cooling 4.5.5 X Not applicable.
Altitude 4.6.1 F2 For installation in non-pressurized locations:
Max. 55000 ft
Overpressure 4.6.3 A2 For installation in pressurized locations:
-15000 ft
Temperature variation 5.0 A Externally mounted: 10°C/minute
Humidity 6.0 C External equipment.
Table A-3: Common environmental conditions and tests (DO160G) for LGA-5005