User Manual

Table Of Contents
Functionality
6-30 Confidential - For internal use 99-137719-D
6.6.4 Fast signal-to-noise reports
During normal run time operation the BGAN XL Radio Module can deliver fast signal-
to-noise reports at an interval of 10 ms. This service is controlled via the parameter
.fast_snr_reporting and is per default deactivated.
6.6.5 Drift distribution
During normal run time operation the BGAN XL Radio Module offers the possibility to
distribute the estimated drift of the clock and the FIFO buffer used for circuit switched
data. Refer to section 11.4 on page 11-10 for details on the drift estimation.
The reporting of the drift estimates is per default deactivated but can be enabled via
the parameters .clk.drift.distribution and .clk.csfifo.distribution.
The drift is distributed to the integrator via a slot on the TSI bus configured by
.clk.drift.slot_no.
6.6.6 AMBE encoding
The .ambe.enable parameter specifies if the internal AMBE+2
TM
encoder shall be
enabled.
Parameter name
protocols.bgan.functionality
External
access
Type /
Domain
Values
[min;max]
Comment
.fast_snr_reporting r/w t4 §4 int / ram [0..1] 0=disable (default),
1=enable
Table 6-33: Special service: fast signal-to-noise reports
Parameter name
protocols.bgan.functionality
External
access
Type /
Domain
Values
[min;max]
Comment
.clk.drift.distribution r/w t3 §4 int / ram [0..1] 0=disable (default),
1=enable
.clk.csfifo.distribution r/w t3 §4 int / ram [0..1] 0=disable (default),
1=enable
.clk.drift.slot_no r/w t3 §4 int / ram [0..31] TSI slot number used for
distribution of drift estimates.
Table 6-34: Configuration of drift estimates