Startup & configuration
choose between full support (in both the forward and return direction) or half support
in either the forward or the return direction.
The .ldr.enable parameter must be activated if the integrator wants a terminal that
supports the use of low data rate (LDR) capabilities. If none of the capabilities are
activated the RM will operate as a standard BGAN modem
A new product will normally have to support extended L-band to get Type Approval
from Inmarsat. However, there can exceptionally be cases where the antenna does not
support the extended frequencies. In such cases the .xl parameter can be used to
disable this functionality.
See also description of PhysicalLayerCapabilityParam in SDM v2c2.
.
The .aeronautical_safety parameter must be set if the integrator makes an aeronautical
terminal with SwiftBroadband Oceanic Safety Service enabled. SwiftBroadband
Oceanic Safety Service is defined in the SDM [18].
The .enhanced_aeronautical_safety parameter must be set if the integrator makes an
aeronautical terminal with Enhanced SwiftBroadband Safety Service enabled.
Enhanced SwiftBroadband Safety Service is defined in the SDM [18].
The 2 parameters will set bit 14 in access class (SDM v3c3 and v3c4) and aeronautical-
safety-services-supported or (maritime-safety-voice-or-)enhanced-aeronautical-
safety-service-supported bit in AdditionalUeCapabilityAVP (SDM v2c2).
The .maritime_safety_voice parameter must be set if the integrator makes a maritime
terminal with Maritime Safety Voice enabled. Maritime Safety Voice is defined in the
SDM [18].
Parameter name
protocols.bgan.functionality
External
access
Type /
Domain
Values
[min;max]
Comment
.aeronautical_safety r/w t3 §4 int / ram [0..1] Aeronautical safety service.
0: Disable (default)
1: Enable
.enhanced_aeronautical_saf
ety
r/w t3 §4 int / ram [0..1] Enhanced aeronautical
safety service.
0: Disable (default)
1: Enable
.maritime_safety_voice r/w t3 §4 int / ram [0..1] Maritime safety service
0: Disable (default),
1: Enable
Table 6-62: BGAN safety capabilities
Note
It is the responsibility of the integrator of the RM to configure the capabilities
so they are in agreement with the Inmarsat BGAN SDM and the BGAN class
configured in section 6.8.1.