Connection types
6-56 Confidential - For internal use 99-137719-D
6.9 Connection types
The following subsections describe the parameters that can be modified by the
integrator to control the behaviour of the different connection types.
6.9.1 Circuit switched parameters
The following parameters are defined for the circuit switched services described in
section 7.5 on page 7-6:
Figure 6-9: Parameter hierarchy for connection parameters.
protocols
sip
pcm
Parameter name
protocols.sip
External
access
Type /
Domain
Values
[min;max]
Comment
.auth.enable r/w t4 §5 int / flash [0..1] Enable/disable authentication.
Requires reboot to take effect.
0: Disable
1: Enable (default)
.user-name r/w t4 §4 string /
flash
n.a. Max length: 30
(default = ‘sip1’)
.password r/w t4 §4 string /
flash
n.a. Max length: 9
(default = ‘sip1’)
.def-call-type r/w t3 §4 int / flash [0..3] 0: Speech (default)
1: 3.1 kHz
2: ISDN RDI
3: ISDN UDI
.codecs r/w t4 §4 string /
flash
n.a. Comma separated prioritized list of
preferred RTP audio codecs.
Supported values are: ‘pcma’ and
‘pcm16’.
Note: Only the first item in the list is
used.
(default=’pcma’)
.pcm.enabled r/w t3 §4 int / flash [0..1] Support for TSI/PCM bus data.
0: Disable (default)
1: Enable
Table 6-75: Circuit switched parameters