User Manual

Table Of Contents
Test-specific protocols
7-40 Confidential - For internal use 99-137719-D
7.8 Test-specific protocols
The following subsections provides information on the protocols supported by the
BGAN XL Radio Module to enable test required for type approval.
7.8.1 BP LT
The terminal communicates with the BGAN Physical Layer Tester (BPLT) by exchanging
messages over TCP connections initiated by the BPLT. The BPLT issues messages to the
terminal to request it to perform operations such as configuring its transmitter or
receiver. The terminal sends acknowledgement messages to the BPLT in response to
each message received. The terminal additionally issues messages to the BPLT to
report received FEC blocks and to support transmission flow control. The BPLT does not
acknowledge messages from the terminal.
Two separate TCP connections are used, one for control and acknowledgement
messages and one for data traffic.
For aeronautical user terminals which require Doppler compensation, UDP datagrams
carrying ARINC-429 messages must be sent to port 3001.
Do not change these port numbers in the BPLT configuration file.
For further details of the communication protocol between the BPLT and the BGAN XL
Radio Module see the BPLT/UT Interface Specification document written by Square Peg
Communications Inc
1
.
For further details of the exchange of messages conforming to the ARINC Specification
429
2
between the BPLT and BGAN XL Radio Module, refer to the BPLT ARINC-429
Interface Specification written by Squarepeg Communication Inc.
See section 12.7.1 on page 12-17 for additional information on the physical BPLT setup.
For a walkthrough of the physical layer scripts needed for validating the performance
of the BGAN XL Radio Module as well as possible special handling of individual scripts
with regards to correctly configuring the BGAN XL Radio Module, refer to 14.3.
Port number Connection TCP UDP
Port 2001 Control connection X
Port 2002 Data connection X
Port 3001 ARINC-429 interface X
Table 7-30: TCP and UDP connections for physical layer tests