User Manual

Table Of Contents
Startup and mandatory configuration
99-137719-D Confidential - For internal use 12-3
12121212
Use cases
12.1.3 Waveform activation (BPLT mode)
This use case presents a simplified procedure describing how a waveform is loaded in
the BGAN XL Radio Module and activated to operate in BPLT mode. The use case
assumes that the RM has already been brought into an active service mode.
1. Load the waveform by sending: MSG_WAVEFORM (load=0, BPLT=1).
2. Wait for acknowledge via the message: MSG_ACK.
3. Read the configuration parameter: 'sys.status.mode' and verify that the RM is in
'standby' state.
4. Provide the RM with additional configuration via the configuration system.
5. Activate the waveform by sending: MSG_WAVEFORM (activate=1, BPLT=1).
6. Wait for acknowledge via the message: MSG_ACK and verify that 'sys.status.mode' is
in 'operating' state.
The BPLT waveform is now active and the RM is ready to receive test instructions from
the BGAN Physical Layer Tester (BPLT).
12.1.4 Waveform activation (BPT mode)
This use case presents a simplified procedure describing how a waveform is loaded in
the BGAN XL Radio Module and activated to operate in BPT mode. The use case
assumes that the RM has already been brought into an active service mode.
1. Load the waveform by sending: MSG_WAVEFORM (load=0, BPT=3).
2. Wait for acknowledge via the message: MSG_ACK.
3. Read the configuration parameter: 'sys.status.mode' and verify that the RM is in
'standby' state.
4. Provide the RM with additional configuration via the configuration system.
5. Activate the waveform by sending: MSG_WAVEFORM (activate=1, BPT=3).
6. Wait for acknowledge via the message: MSG_ACK and verify that 'sys.status.mode' is
in 'operating' state.
The BPT waveform is now active and the RM is ready to receive test instructions from
the BGAN Protocol Tester (BPLT).