User Manual

Table Of Contents
Services
12-16 Confidential - For internal use 99-137719-D
protocols.bgan.functionality.satellite_table.change.channel.alternate to the new
values.
5. Set protocols.bgan.functionality.satellite_table.change.default to 0.
6. Reset protocols.bgan.functionality.satellite_table.change.locked to indicate that the
parameters have been updated and are ready to be used.
7. The RM will now read the changed values and update the satellite table. The
satellite table will only be update if the .satellite_id set in step 3 already exists.
12.6.5 Reset satellite table to default
If the satellite table manually has been altered (section 12.6.4) to fit some test
scenarios, it may eventually be necessary to reset it to default.
This use case illustrates how to reset the satellite table to default.
1. Put the RM into 'waveform mode' (refer to section 12.1.2).
2. Set the parameter protocols.bgan.functionality.satellite_table.change.locked to 1
indicating that the parameters are being updated.
3. Set protocols.bgan.functionality.satellite_table.change.default to 1.
4. It is not necessary to set any of the other
protocols.bgan.functionality.satellite_table.change parameters.
5. Reset protocols.bgan.functionality.satellite_table.change.locked to indicate that the
parameters have been updated and are ready to be used.
6. The RM will now reset the satellite table.