User Manual

Table Of Contents
System
99-137719-D Confidential - For internal use 6-15
6666
Startup & configuration
6.4.3 BGAN XL Radio Module temperature
The internal temperature of the BGAN XL Radio Module is stored in the configuration
system. The parameter is updated every time the temperature changes 1°C.
Less than 3°C temperature difference to case temperature can be expected by the on-
board temperature sensor. Temperature monitoring is described in 10.3.3 on page 10-
12.
6.4.4 Software updated
The BGAN XL Radio Module sets this parameter to ‘1’ when the software has been
updated using the procedure described in section 11.2 on page 11-3.
Parameter name
sys
External
access
Type /
Domain
Values
[min;max]
Comment
.mainboard.tem
perature
r int / ram [-55..
+125]
Temperature in degrees Celsius (°C).
Values correspond to the working
area of the sensor.
.overheat_protec
tion.reboot
r/w t4 §4 int / ram [0..1] Determines if the BGAN XL Radio
Module shall reboot if the
temperature gets critically high.
1: Reboot is performed (default)
0: Reboot is disabled
.overheat_protec
tion.alarm
r/w t4 §4 int / ram [0..1] Determines if a message is sent (see
8.5.6.1) if the temperature gets
critically high.
1: Message is enabled (default)
0: Message is disabled
Table 6-9: Configuration parameter: BGAN XL Radio Module temperature
Parameter name
sys.sw
External
access
Type /
Domain
Values
[min;max]
Comment
.updated r int / ram [0..1] 0: Not updated
1: Software has been updated
Table 6-10: Software updated parameter