99-137719-D Confidential - For internal use 6-17
6666
Startup & configuration
6.4.7 Terminal serial number (FOR INTERNAL USE)
The integrator must, upon startup, write the serial number of the terminal into the
configuration parameter sys.terminal.serial
6.4.8 RM serial numbers
The serial number of the RM is the last ten digits of the 20-digit PCB ID. The PCB ID can
be found in the configuration parameter sys.pcbid, and is stored as an ASCII string.
Note
Note that the parameters .rxslots, .txslots, .rxdatdly, .txdatdly, must be
configured before the parameter .enabled is activated as they are only read
once.
Parameter name
sys
External
access
Type /
Domain
Values
[min;max]
Comment
.terminal.serial r/w t1 §1 string/
ram
n.a. Max. 200 characters
Table 6-13: Terminal serial number
Important
This is for internal use only and only intended to be used for E710 units
that have not been produced with SIM Lock code. For new products the
SIM Lock code must be written during production. Otherwise the SIM Lock
feature will not be secure.
Parameter name
sys
External
access
Type /
Domain
Values
[min;max]
Comment
.pcbid r byte
array/
factory
n.a. A 20 character ASCII string
representing the serial number (or
pcb id) of the unit.
Table 6-14: Radio Module serial number