Technical Manual

5
Installation
IRIDIUM
2.3 Cable Overview
Cable 1
Scanbus
Cable: 9*0.22 mm
2
shielded
shield connected to ground
Cable connector type: 9 pole sub-d male
Transceiver Description Handset Colour
1NC1
2 data+ 2 white Twisted
3 data- 3 brown pairs
4AF+4greenTwisted
5 AF- 5 yellow pairs
6 GND 6 grey Twisted
7 +24V DC 7 pink pairs
8 RX_AF+ 8 blue Twisted
9 RX_AF- 9 red pairs
shield GND shield
2
3
4
5
6
7
8
9
1
10
36088
0514
Cable 2
Phone
Cable connector type: RJ 11
Transceiver Description
1NC
2 phone1+
3 phone1-
4NC
Cable 3
Data
Cable: 9*0.22 mm
2
shielded
shield connected to ground
Cable connector type: 9 pole sub-d male
Transceiver Description
1DCD
2 received data
3 transmitted data
4 data terminal ready
5serial GND
6 data set ready
7 request to send
8clear to send
9RI
shield GND
Cable 4
Power supply
Pin no. Description Colour
1 10-32V DC red
20V DC black
3NC white
4 GND green
Front view
4
3
1
2
36662A