Instructions / Assembly

To install unit:
1. With the EF536 Post Driver laying on the ground surface, slip the
Earthflex™ soil anchor on the lower section in contact with driver. Prior to
raising the anchor and tool to a vertical position, be certain to position
anchor so that locking tabs will be perpendicular to the flow of traffic.
2. When using power tools, be certain to keep the anchor vertically plumb
while driving it into the ground to insure that the installed post will be
vertically straight. Be certain to position anchor so that locking tabs will
be perpendicular to the flow of traffic.
3. Drive anchor until it is ½” below the surface to insure there is no exposed
portion of the anchor above grade to damage the post or expose the
installer or contractor to potential damage liability claims.
4. Insert post in anchor past the locking tabs, pull up post to lock in place.
Post/Hinge Removal:
1. Spray base of post/hinge assembly at anchor with WD-40 or equal
lubricant.
2. Gripping the post 6” above ground, push down two inches, turn post one
inch left or right and pull up to remove.
3. Spray inside of anchor with WD-40 prior to inserting a new post/hinge
assembly.