Assembly Instructions
I.S. 19
hanging instructions
start here
SAFETY WARNING: READ WIRING AND GROUNDING
INSTRUCTIONS (I.S. 18) AND ANY ADDITIONAL DIRECTIONS. TURN
POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS
REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL
AUTHORITIES FOR CODE REQUIREMENTS.
1. Shut off electrical current before starting. If the fixture you are replacing is turned on
and off by a wall switch, simply turn the switch off. If not, remove the appropriate fuse
(or open the circuit breakers) until the fixture is dead.
1. Fasten mounting strap (1) to outlet box (A) with the two 8-32 screws (2) – see
Drawing 1.
2. Thread 2 - hex nuts (3a) and (3b) onto threaded tubing (4).
3. Thread one end of threaded tubing (4) into loop (5) a minimum of 1/2” to 3/4”. Tighten
hex nut (3a) against loop (5) to lock loop in position.
4. Thread other end of threaded tube (4) into mounting strap approximately 1/2”.
5. Slip canopy (B) over loop (5) and adjust height of loop so half of the threaded area on
6. Remove mounting strap (1) from junction box (A), and thread third hex nut (3c) onto
end of threaded tube (4) above the mounting strap, tighten against mounting strap to
lock assembly in position.
7. Remount mounting strap to junction box.
1. Taking the chain, determine the length you require to hang the fixture.
2. Attach one end of the chain to the top loop of the fixture.
3. Now slip loop collar (6) and canopy (B) onto chain. – see Drawing 2
4. Attach other end of chain to loop (5). Get assistance for this step since fixture may be
heavy and difficult to hold while attaching the chain.
1. Unwrap fixture lead wire and ground wire and weave them up through the chain.
2. Slip fixture lead wire and ground wire through center of loop (5).
3. Connect ground wire to mounting strap (1) using green ground screw (GS).
4. Make electrical connections from supply wire to fixture lead wires. Refer to
instruction sheet (I.S. 18) and follow all instructions to make all necessary wiring
connections.
5. Slip canopy up firmly against the ceiling and secure by turning the threaded collar
(6) on loop (5) until tight.
I.S. 19
instructions suspendues
commencez ici
AVERTISSEMENT DE SECURITE: LIRE CABLAGE ET INSTRUCTIONS DE
MISE (IS 18), ET TOUTE AUTRE INSTRUCTION. COUPER
L’ALIMENTATION ELECTRIQUE PENDANT L’ONSTALLATION. SI DE
NOUVELLES CABLAGE N’EST NECESSAIRE, CONSULTEZ UN
ELECTRICIEN QUALIFIE OU AUTORITES LOCALES POUR EXIGENCES
DU CODE
1. Couper le courant électrique avant de commencer. Si l’appareil vous remplacez est
activé et désactivé par un interrupteur mural, il suffit de tourner l’interrupteur. Sinon,
retirez le fusible approprié (ou ouvrez les disjoncteurs) jusqu’á ce que l’appareil est
mort.
Ne pass restaurer actuel – soit par fusible, disjoncteur ou interrupteur – jusqu’á ce
que le nouvel appareil est entiérement cable et en place.
1. Fixer sangle de fixation (1) á la boîte de sortie (A) avec les deux vis 8-32 (2) – Voir
Schéma 1.
2. Sujet 2 – écrous hexagonaux (3a) et (3b) sur le tube fileté (4).
3. Rnfilez une extrémité d’un tube fileté (4) dans la boucle (5) d/un minimum de 12.7mm
á 19.05 mm. Serrez l’écrou hexagonal (3a) á l’encontre de boucle (5) pour verrouiller
la boucle en position.
4. Filautre extrémite du tube fileté (4) dans la sangle de fixation d’eviron 12.7 mm.
5. Glissez canopée (B) sur la boucle (5) et régler la hauteur de la boucle anisi la moitié
6. Supprimer étrier de montage (1) á partir de la boîte de jonction (A), et le troiseiéme
écrou hexagonal de fil (3c) sur l’extrémité du tube fileté (4) au-dessus de la bande de
montage, serrer contre la sangle de fixation pour bloquer l’assemblage en position.
7. Sangle de fixation remonter á la boîte de jonction.
1. Prenant la cgaíne, determiner la longueur don’t vous bensoin pour accrocher
l’appreil.
2. Fixez une extrémité de la chaîne á la boucle supérieure de l’appareil – Voir Schéma
2.
3. Repredre collier en boucle (6) et la voûte (B) sur la chaîne.
4. Attacher autre extrémité de la chaîne á boucle (5). Obtenir de l’aide pour cette étape
depuis luminaire peut être lourd et difficile á tenir tout en attachant la chaîne.
1. Déroulez cable d’alimentation et cable de terre et les tisser á travers la chaîne.
2. Glissez fournir des fils et fil de terre á travers la centre de la boucle (5).
3. Connectez le fil de terre á la sangle de fixation (1) avex la vis de terre verte (GS).
4. Effectuez les connexions électriques du câble d’alimentation á fils de connexion du
projecteur. Roportez-vous á la feuille díntruction (IS18) et suivez toutes les
instructions pour effectuer tous les brachements nécessaires.
5. Glissez verriére fermement vers le haut contre le plafond et sécuriesé en tournant la
baque filetée (5) sur la boucle (4) iusqu’á la buttée.
I.S. 19
instrucciones para colgar
empieza aquí
ADVERTENCIA DE SEGURIDAD : LEA LAS INSTRUCCIONES DE
HACER LAS CONEXIONES ELECTRICA Y ALAMBRE DE
CONEXION A TIERRA (I.S.18) Y INSTRUCCIONES ADICIONALES.
APAGUE ALIMENTACION DE CORRIENTE DURANTE
INSTALACION. SI SE REQUIERE CABLEADO NUEVO, CONSULTE
CON ELECTRICISTA CALIFICADO O LAS AUTORIDADES
LOCALES PARA REQUERIMIENTOS DEL CODIGO.
1. Apague la corriente elécrica antes de comenzar. Si el luminario que vas a
reemplazar se prende y se apaga por un interruptor de pared, simplemente
apaga el interrupto. Si no es asi, quite el fusible apropiado (o abrir los
interruptores de circuito) hasta que el luminaria está sin corriente.
No restaure el corriente – por medio de fusible, interruptor o interruptor de
circuito– hasta que la luminaria nueva está completamente conectado y en su
lugar.
1. Apriete la correa de montaje (1) de la caja de conexiones (A) con los dos
tornillos 8-32 (2) – Véase la Figura 1.
2. Rosca 2 – tuercas hexagonales (3a) y (3b) en el tubo roscado (4).
3. Pase un extremo de el tubo roscado (4) en el bucle (5) un minimo de 1/2" a
3/4". Aprieta la tuerca hexagonal (3a) en contra de bucle (5) para fijar bucle en
posición.
4. Rosca el otro extremo de tubo roscado (4) en la correa de montaje
aproximadamente 1/2".
5. Desliza el dosel (B) sobre bucle (5) y ajustar la altura de bucle así que la mitad
de la zona roscada en el bucle está expuesta – Véase la Figura 2 abajo.
Después que la bucle esta ajustada, apriete la tuerca hexagonal (3b) contra la
correa de montaje para que se quede en posicion.
6. Quite la correa de montaje (1) de la caja de conexiones (A),y rosca la tercera
tuerca hexagonal (3c) en el extremo del tubo rosacdo (4) por encima de la
correa de montaje, apriete contra la correa de montaje para fijar la posición de
montaje.
7. Montar de nuevo la correa de montaje a la caja de conexiones.
1. Tomando la cadena, determina la longitud que usted necesita para colgar el
luminaria.
2. Conecte un extremo de la cadena en el bucle de la parte superior de la
luminaria.
3. Ahora deslice el collar de el bucle (6) y el dosel (B) en la cadena. – Véase la
Figura 2.
4. Conecte el otro extremo de la cadena al bucle (5). Recibe la ayuda para este
paso ya que la luminaria puede ser pesado y difficil de mantener mientras se
conecta la cadena.
1. Desenrollar cables conductore y alambre de conexion a tierra y tejen a través
de la cadena.
2. Deslice el cables conductores y alambre de conexion a tierra a traves del
centro del bucle (5).
3. Conecte el alambre de conexion a tierra a la correa de montaje (1) con el
tornillo verde de conexion a tierra (GS).
4. Haga los conexiones eléctricas de los cables de alimentación a los cables
conductores del luminaria. Referirse la pagina de instrucciones (I.S.18) y siga
todas las instrucciones para hacer todas las conexiones necesarias.
5. Con firmeza deslice el dosel contra el techo y asegure girando el collar roscado
(6) en el bucle (5) hasta que quede apretado.
Drawin
g
2
–
Cano
py
Ad
j
ustment
Drawin
g
1
–
Han
g
in
g
Instruction
DO NOT restore current - either by fuse, breaker or switch - until the new fixture
is completely wired and in place.
the loop is exposed - see Drawing 2 below. After loop height is adjusted, tighten hex
nut (3b) up against mounting strap, tighten against mounting strap to lock loop and
threaded tube in position.
de la partie filetée de la boucle est exposée – voir dessin 2 ci-dessous. Aprés
hauteur de boucle est ajustée, serrez l’écrou hexagonal (3b) contre sangle de
fixation, serrez contre sangle de fixation pour verrouiller la boucle et le tube fileté en
position.