Product Manual

7
Safety Precautions
VIEW AND PROGRAM SETTINGS
Load Delay
Display shows the delay time for load disconnect. To adjust the load delay,
press and hold the menu button (>5 seconds), once the numbers start
flashing, use the arrow buttons to change the voltage. To save the settings
and return to normal view, press and hold the menu button (>5 seconds).
The delay can be set in increments of 1 hour from 0 - 24hrs. If set to 24h,
the load circuit will remain on at all times, provided there are no faults
detected. If set 1 - 23h, the load circuit will remain on that many hours after
solar input cuts out. If set to 0h, the load circuit will only be active without
solar input.
Common Fault Codes and Handling
Overload: The screen will display as shown, meaning that over 30A is
trying to be drawn from the load circuit. To remedy, reduce the load, press
the menu button then press the down arrow to restore power to the circuit.
Short Circuit
The screen will display as shown. To remedy, check all cables and remove
the short, press the menu button then press the down arrow to restore
power to the circuit.