OPERATION
Operation
DISPLAY REMOTE DESCRIPTION
b1 Off Main battery is connected to the main stud (only occurs when connecting the battery isolator to the vehicle).
b2 Off Auxiliary battery is connected to aux stud (only occurs when connecting the battery isolator to the vehicle).
On/Blank On Batteries are linked and the auxiliary battery can be charged from the main battery.
Off Off The battery isolator has disconnected the circuit.
O-n Flashing
The remote override has been activated and the batteries are now linked. The batteries are linked for approximately 10 seconds.
At the end of this time period the battery isolator will again disengage the batteries.
b-L Flashing The battery isolator has detected the auxiliary battery voltage to be lower than the alarm voltage and has disengaged batteries.
b-L Off
The battery isolator has detected the main battery is lower than the alarm voltage. WARNING: Check all connections to the
main battery, if possible check voltage and visually inspect battery. The auxiliary battery can be used to start the vehicle by
activating the remote switch.
b-H Off
The battery isolator has detected an overvoltage (higher than 17 volts). WARNING: Check alternator output if possible. If the
auxiliary battery is connected to an alternate power supply (solar or charger) check output from supply.
b-N Off
Voltage lower than 8.8 volts detected. WARNING: This would indicate catastrophic failure of one or both batteries. Carefully
check both batteries before proceeding.
I-P Off Indicates main battery open circuit (loose or damaged cabling). Check all connections and wiring to the main battery.
O-t Off The battery isolator has detected excessive temperature (+80°C) and has shut down. Unit will reactivate at +60°C.
Once your battery isolator is installed and the set points are programmed it is operational at all times. All functions can be visually checked by either the remote indicator
or the LED readout on the unit.