REVERSE CHARGING SYSTEM
In a number of situations, the auxiliary battery may need to be connected to a solar
input or additional charging system. The battery isolator will recognise that the
auxiliary battery is receiving charge and if the main battery is below 12.8 volts and
the auxiliary battery is above 13.36 volts and receiving a charge, the battery isolator
will open the circuit and allow the auxiliary battery to charge the main battery. The
battery isolator will display 'on' and the remote switch LED will turn on.
Reverse Charging System