Data Sheet

Statement
1. Conformity Assessment of the Radio Module to the RED
This radio module is for professional installation only. When installing this radio module
permanently into a host product to a create new radio equipment device; the manufacturer
responsible for placing the final radio product on the market in the EU must assess if the
combination of this radio module and the host product complies with the essential
requirements of the RE Directive 2014/53/EU.
2. Firmware version:
Test Antenna: PIFA Antenna and maximum gain 2dBi.
The final radio product will need to be fully assessed to Article 3.1a of the RED, for product safety
With regard to RF exposure for Article 3.1a of the RED, the manufacturer of the final radio product
will need to assess if the compliance assessment of the original radio equipment/module remains
relevant to the final radio product, or if further action is necessary.
This equipment should be installed and operated with minimum distance 20cm between the
radiator& your body.
If the final radio equipment is used at the same distance from a person or domesticated animal as
the radio module was assessed, (for example: >20cm), then the final radio product assessment
could conclude that the final radio product is compliant with the RF exposure requirements
without additional actions.
If the final radio equipment is used at a closer distance from a person or domesticated animal
than the radio module was assessed, then the final radio product assessment could not
automatically conclude that the final radio product is compliant with the RF exposure
requirements without additional actions; and further assessment is necessary.
The final radio product will need to be fully assessed to Article 3.1b of the RED, for EMC.
EMC testing of the radio module will have been performed on some sort of temporary host or test
jig; but now the module is in a new host product and the EMC performance of the final radio
product must be assessed. Most likely the host product will have its own EMC assessment for
other functions, which should be performed with the radio module installed; and inclusion of the
radio module into the host product will also require an assessment, such as to the relevant
applicable part of EN 301 489, on the final radio product.
In theory, radio transmitter or receiver measurements made as conducted measurements at a
radio module antenna port may be considered applicable to the radio performance of the final
radio product. However, in this example, the radio module does not have an antenna port. The
radio module has a pin which leads through a PCB trace to an antenna on the host product. If the
manufacturer of the final radio product wishes to use conducted power, conducted emissions or
receiver performance measurements from the radio module to show compliance of the final radio
product, then they will need to exactly follow the detailed instructions from the radio module
manufacturer; including input voltage, driver software, environmental conditions, antenna trace
layout design construction and material, circuit board layout design construction and material,
Copyright© 2020 Thundercomm Technology Co., Ltd. All rights reserved.
26
TurboX C610 SOM DATASHEET