Use and Care Manual
2 4 6 8 10 12 14 16 18 20
(7.6) (15) (23) (30) (38) (45) (53) (60) (68) (76)
7
(0.48)
6
(0.41)
5
(0.35)
4
(0.28)
3
(0.21)
2
(0.14)
1
(0.07)
*
*
*
Shown with differential gauge.
Gauges sold seperately.
Flow Rate – gpm (lpm)*
*Pressure drop and ow rate based on housing without
cartridge.
Approximate Net Pressure Drop – psi (bar)*
Housing Specifications and Performance Data
Model Maximum Dimensions Initial ∆P (psi) @ Flow Rate (gpm)
3G #10 Blue or Clear MB 12
3
⁄4" x 5
3
⁄8" (324 mm x 137 mm) 1 psi @ 10 gpm (0.07 bar @ 38 Lpm)
3G #10 Blue or Clear MB 13
1
⁄4" x 5
3
⁄4" (337 mm x 146 mm) 1 psi @ 10 gpm (0.07 bar @ 38 Lpm)
3G #20 Blue or Clear MB 23" x 5
3
⁄8" (597 mm x 137 mm) 1 psi @ 10 gpm (0.07 bar @ 38 Lpm)
3G #20 Blue or Clear IB/MM* 23
1
⁄2" x 5
3
⁄4" (597 mm x 146 mm) 1 psi @ 10 gpm (0.07 bar @ 38 Lpm)
Materials of Construction
Housing Polypropylene (Opaque) or Styrene Acrylonitrile (Clear)
Cap Reinforced Polypropylene
Button Assembly 300-series Stainless Steel, EPDM, and Polypropylene
O-Ring Buna-N
Maximum Temperature 125ºF (51.7ºC)
Maximum Pressure 125 psi (8.62 bar)
CAUTION: Protect against freezing to prevent cracking of the lter and water leakage.
3G SERIES
Standard Filter Housings
502 Indiana Avenue • P.O. Box 1047 • Sheboygan, Wisconsin 53082-1047
Customer Service: 800.645.0267 • Fax: 888.203.7361 • supportspecialist@pentekltration.com
International: 920.457.9435 • Fax: 920.457.2417 • international@pentekltration.com
©2007 Pentair Filtration, Inc. www.pentekltration.com Printed in USA FE07 310103