Use and Care Manual
10
NOTE
Some medias like those used in NU Models are
sacrificial and deplete faster depending on inlet
water conditions and usage. The media replenish-
ment is more frequent in high water usage and more
acidic water cases. The dome hole models are
available and supplied in which the dome hole is
available for a quick addition or replenishment of
media in the tank.
CAUTION: Make sure the power cord of the
valve doesnt get caught between the threads
Grease port Orings using
brush (not included) or
your finger (Make sure to
wear protective gloves)
D-Tube
Unscrew Spill Cap
Attach
Upper
Basket
Lube the bottom Valve Orings with the grease supplied, Attach the Upper Basket. Unscrew the spill cap.
Carefully Slide the D-Tube inside the Valve and Screw the Valve inside the Tank such that the power cord doesn’t
get caught between the valve and the tank.
Unplug the riser tube, carefully position the valve over it and turn the valve into the threads in the berglass tank,
tightening securely into tank. Note: Ensure that the internal O-ring in the valve ts securely over the riser tube.
Silicone grease (part # 92360) or other food grade lubricant may be applied to the O-ring to ease installation of the
riser tube.
Neutralizing
Filter (NF)
Media Bed
Calcium
Carbonate &
Magnesium Oxide
Mixed
(Grey / White)
Support Bed
(when supplied)
Fine, Medium
and/or Coarse
Gravel
Activated Carbon
and Catalytic
Carbon Unit
Carbon
(Black)
Support Bed
(when supplied)
Fine, Medium
and/or Coarse
Gravel
O-ring
PREPARATIONS
CAUTION!
Make sure that the
unit is de-pressurized
before conducting
this task.
CAUTION!
DO NOT use petroleum
based lubricants as they
will cause swelling of
O-ring seals.