Use and Care Manual
4 5
Water and Time Consumed During Regeneration
Unit Size
Backwash
Minutes
Rapid Rinse
Minutes
Total Time of
Regeneration
Total Water
Consumed during
Regeneration (GAL)
(TO, NU, CLA)
100 10 10 20 80
150 10 10 20 100
Model Media
Cu Ft
Flow Rate USGPM Micron
Rating
Mineral
Tank Size
Pipe Size
Inches
Ship
Weight Lbs
Service Peak Backwash
Taste & Odor Filters
CB-BW-948
1.00 5.0 7.0 4.0 - 9 x 48 3/4” - 1” 60
1.50 7.0 10.0 5.0 - 10 x 54 3/4” - 1” 78
Neutralizing Filters
CHLRM-RED-948
1.00 3.0 5.0 4.0 - 9 x 48 3/4” - 1” 120
1.50 5.0 8.0 5.0 - 10 x 54 3/4” - 1” 164
Chloramine Filters
CALCITE-BW-948
1.00 5.0 8.0 4.0 - 9 x 48 3/4” - 1” 120
1.50 8.0 10.0 5.0 - 10 x 54 3/4” - 1” 155
SPECIFICATION
Working Temperature = 34-110°F (1-43°C)
(Do not subject the unit to freezing temperatures)
Working Pressure = 30-125 PSIG (137-861 kPa)
Voltage = 120V / 60 Hz
Pipe Size = 3/4” and 1”
• At the stated service flow rates, the pressure drop
through these devices will not exceed 15 psig.
• The manufacturer reserves the right to make
product improvements which may deviate from the
specifications and descriptions stated herein, without
obligation to change previously manufactured products
or to note the change.
* Do not use water that is microbiologically unsafe
without adequate disinfection before or after the
system.
Peak flow rates intended for intermittent use only (10
minutes or less) and are for residential applications only.
Do not use peak flow rate for commercial applications
or for a continuous rate when treated water supplies are
geothermal heat pump, swimming pool, etc.
For satisfactory operation, the pumping rate of the
well system must equal or exceed indicated backwash
flow rate.
All units come with plastic bypass
CB-BW-1054
CHLRM-RED-1054
CALCITE-BW-1054