CAUTION!
Never subject your conditioner
to freezing, vacuum
or direct sun light.
Service Schedule
The seals and spacers along with the piston assembly should be inspected/cleaned or replaced every year depending on the inlet water quality and water usage on clean
municipal supplies every 2 - 3 years should be sucient but the rst check should be done after 1 year. See inspection and replacement of Piston assembly and seal and spacer
kit, page 26.
The injectors should be cleaned/inspected or replaced every year depending on the water quality and use. See Clean Injector Assembly, page 27.
Maintenance Kit (60010564) should be used for servicing control on an annual basis. The maintenance kit consists of piston assembly, seals and spacers, injectors.
Maintenance of your new water conditioner requires very little time or eort but it is essential. Regular maintenance will ensure many years of ecient and trouble free operation.
FAILURE TO FOLLOW BASIC MAINTENANCE SCHEDULE WILL RESULT IN THE UNIT FAILING TO OPERATE PROPERLY AND VOID YOUR
WARRANTY.
CAUTION!
Liquid brine will irritate eyes,
skin and open wounds -
gently wash exposed area
with fresh water. Keep
children away from
your water conditioner.
Bridging
Humidity or the wrong type of salt may create a cavity between the water and
the salt. This action, known as “bridging”, prevents the brine solution from
being made, leading to your water supply being hard.
If you suspect salt bridging, carefully pound on the outside of the plastic brine
tank or pour some warm water over the salt to break up the bridge. This should
always be followed up by allowing the unit to use up any remaining salt and
then thoroughly cleaning out the brine tank. Allow four hours to produce a
brine solution, then manually regenerate the
softener.
Cleaning of your Brine / Salt tank
Salt tanks will build up sludge (undissolved salt) in the bottom of them that will continue to increase as time goes by. Every 2 - 3 years the salt tank should be cleaned out
completely and re started using the original start up instructions.
MAINTENANCE INSTRUCTIONS AND SCHEDULE
System Check List
NOTE** All units are factory programmed for the correct size and regeneration cycle alteration should only be done by a factory
trained technician or after consultation with one of our technical representatives if you have any questions please call:
1-855-378-9116
4a. Open the inlet on the bypass valve slightly and very slowly allow water to enter the unit. (If the water enters too quickly it will push the media up into the control valve and
get plugged).
Once the unit has lled suciently that water is at least equal to the height of the top of the media shut down the water for 15 – 20 minutes for the media bed to soak. Unplug the
power cable. After the media bed has soaked for the recommended time continue.
4b. Open the inlet on the bypass valve slowly and allow water to enter the unit. (The outlet of the bypass should remain closed to prevent any nes or debris from entering the
plumbing system. Allow all air to escape from the unit before turning the water on fully then allow water to run to drain for 3-4 minutes, or until the water at the drain
appears to be clear of any nes.
4c. Plug in the valve. Allow the valve to continue its cycles until complete and back in service
4d. The Valve is already programmed from factory. Please set up date and time of day and feedwater iron as shown below: