Commission the Tigo equipment
Internet
- + B A
- + B A
Install TAP(s)
Create physical system map
3.
4.
Ensure AC power and Internet availability and
plan RS485 route for Tigo Access Point (TAP)
Congure system online
or with Tigo SMART app
Use the Tigo SMART app to congure the Internet
connection (wired Ethernet or Wi-Fi.)
Select Start Discovery in the app to begin scanning
for TS4 units.
Use TS4 key to open TAP cover.
Connect TAPs in series,
leaving the resistor in the nal TAP
and removing all others.
For best results place at least 5 modules with
TS4 units within 33ft (10m) of a TAP.
Log in to the Tigo SMART app or tigoenergy.com with
your installer account and create a New Installation.
Follow the steps in the site builder to create the new
system. You'll need module and inverter type, as well
as the barcodes from the CCA and TS4 units.
To create a map of the system that matches the
physical layout*, remove the peel-off stickers from
the TS4 covers or record the barcodes on a
map that represents their physical location.
1. 2.
Connect all communication wires before powering on CCA.
Read Installation and Safety Manual
and download Tigo SMART app
Cloud Connect Advanced (CCA) Quick Start Guide
Discovery should be initiated from the Tigo SMART app
while on-site and connected to the CCA.
After commissioning, powering down the CCA and
inverter deactivates the system.
5.
Verify wiring polarity before connecting TAP(s)
The Cloud Connect Advanced (CCA) requires AC
power, an Internet connection (Ethernet or Wi-Fi), and
an RS485 communication cable connection to the
TAP(s).
Install the CCA on the same AC main service as the
inverter to activate rapid shutdown when the AC
disconnect is switched off.
Connect communication wires before powering on the CCA.
Use the Tigo SMART app or site builder at
tigoenergy.com to edit the system map.