TS4 Brochure

Tigo Optimizers get the maximum energy output from your array
and minimize the losses from shading, module mismatch,
degradation, and other issues.
Increase energy output
OPTIMIZATION
Tigo gives you granular, module level monitoring with its Energy
Intelligence Platform. Diagnose anomalies at the module level,
increase bankability, and lower maintenance expenses.
Lower operating expenses
MONITORING
Dedicated, reliable
rapid shutdown
devices
SCHEMATI C , F, 2F
Monitoring enabled
smart devices
SC H EMATI C | O,S,M
Tigo solutions meet US NEC Rapid Shutdown compliance and
other safety codes that protect rst responders and are required
in many countries.
Enhance safety and compliance
RAPID SHUTDOWN
Enhance the economics of your PV system
Tigo TS4 Flex MLPE
O
Tigo MLPE
DONOT DISCONNECT
UNDERLOAD
NEC690.12-2017andC22.1-2015Rule 64.218
4 - 123A
TS4-A-O
S
Tigo MLPE
DONOT DISCONNECT
UNDERLOAD
NEC690.12-2017andC22.1-2015Rule 64.218
4 - 123A
TS4-A-S
M
Tigo MLPE
DONOT DISCONNECT
UNDERLOAD
NEC690.12-2017andC22.1-2015Rule 64.218
4 - 123A
TS4-A-M
F
Tigo MLPE
DONOT DISCONNECT
UNDERLOAD
NEC690.12-2017andC22.1-2015Rule 64.218
4 - 123A
TS4-A-F
Whether you need to meet safety code, want module level visibility or to reduce the impacts from shading, Tigo has you
covered. With Tigo TS4, you can mix and match any of the features listed below.
With Tigo, only pay for
what you need to
maximize the benet of
your PV installation.
Image courtesy:
Go Run Solar
Rapid Shutdown Rapid Shutdown Rapid Shutdown
Monitoring Monitoring Monitoring
Optimization
CCA & TAP CCA & TAP CCA & TAP RSS Transmitter
May be selectively
deployed
May be selectively
deployed
May be selectively
deployed
TS4-A-2F serves 2
PV modules with 1
device
TigoRapidShutdown
DONOTDISCONNECT
UNDERLOAD
NEC690.12-2017andC22.1-2015Rule64.218
4-123A
TS4-A-F
TigoRapidShutdown
DONOTDISCONNECT
UNDERLOAD
NEC690.12-2017andC22.1-2015Rule64.218
4-123A
TS4-A-F
TigoRapidShutdown
DONOTDISCONNECT
UNDERLOAD
NEC690.12-2017andC22.1-2015Rule64.218
4-123A
TS4-A-2F
Rapid
Shutdown
System
Transmitter
accesspoint
AUX RS485-1 RS485-2GATEWAY POWER
TigoRapidShutdown
DONOTDISCONNECT
UNDERLOAD
NEC690.12-2017andC22.1-2015Rule64.218
4-123A
TS4-A-S
TigoRapidShutdown
DONOTDISCONNECT
UNDERLOAD
NEC690.12-2017andC22.1-2015Rule64.218
4-123A
TS4-A-O
TigoRapidShutdown
DONOTDISCONNECT
UNDERLOAD
NEC690.12-2017andC22.1-2015Rule64.218
4-123A
TS4-A-M
TigoRapidShutdown
DONOTDISCONNECT
UNDERLOAD
NEC690.12-2017andC22.1-2015Rule64.218
4-123A
TS4-A-O
1. TS4: O, S, M
Tigo TS4 units are connected to each
module. Customers can selectively
deploy any combination of the TS4-A-O,
S, or M products to maximize returns for
their particular site.
FEATURES
REQUIRED
SEE SCHEMATIC BELOW
OPTIONS
1. TS4: F or 2F
Tigo's Fire Safety line of TS4 are
completely dedicated to the rapid
shutdown function and communication
via PLC with the RSS Transmitter.
2. CCA & TAP
Tigo's Cloud Connect Advanced (CCA) is
the data hub for TS4s and other devices
(inverter, battery, etc.). It connects with
an RS485 cable to the TAP which
wirelessly communicates with TS4s.
2. Required: RSS Transmitter
The Tigo Rapid Shutdown System (RSS)
Transmitter enables UL PVRSS certied
rapid shutdown with TS4-A-F and 2F
units to meet required safety codes.
1
1
2
2
2
3. Tigo Energy Intelligence
All of the module-level data, and any
third party data connected to Tigo's CCA
can be viewed in Tigo’s Energy
Intelligence monitoring system.
3. Monitoring: Inverter
Tigo's TS4-A-F and -2F are dedicated
rapid shutdown devices. Inverter
monitoring may provide DC data at the
string, MPPT or array level.
Contact us
https://www.tigoenergy.com/contacts
Copyright Tigo Energy, Inc. 2021
Contact us
https://www.tigoenergy.com/contacts