User's Manual

TigoMaster 2TH User Manual
Page 29 of 36
CONFIDENTIAL
Copyright © 2020 CoreTigo Ltd.
Byte
Number
of bytes
Output process data
Description
176
1 byte
Padding byte
Do not use
177 … 208
32 byte
IO-Link port 6 process output
data
IO-Link output data of the sensor/actor connected to Port 6.
For a description of the data, see manual of the
manufacturer of the used sensor/actor.
209
1 byte
IO-Link Port 7 Output enable
0: IO-Link Port 7 output data not valid. 1-
255: IO-Link Port 7 output data valid.
210
1 byte
Padding byte
Do not use
211 … 242
32 byte
IO-Link port 7 process output
data
IO-Link output data of the sensor/actor connected to Port 7.
For a description of the data, see manual of the
manufacturer of the used sensor/actor.
243
1 byte
IO-Link Port 8 Output enable
0: IO-Link Port 8 output data not valid. 1-
255: IO-Link Port 8 output data valid.
244
1 byte
Padding byte
Do not use
245 … 276
32 byte
IO-Link port 8 process output
data
IO-Link output data of the sensor/actor connected to Port 8.
For a description of the data, see manual of the
manufacturer of the used sensor/actor.
Table 36: Output process data
The following table shows the mapping of the process output data (DO data) for port-based or pin-based
layout.
Process data layout
Mapping / Sequence of the process data
Port-based
Bit 0 = Port 1 Pin 4, Bit 1 = Port 1 Pin 2,
Bit 2 = Port 2 Pin 4, Bit 3 = Port 2 Pin 2,
Pin-based
Bit 0 = Port 1 Pin 4, Bit 1 = Port 2 Pin 4,
Bit 2 = Port 3 Pin 4, Bit 3 = Port 4 Pin 4,
Bit 8 = Port 1 Pin 2, Bit 9 = Port 1 Pin 2,
Input process data
Table 37: Mapping of the digital output process data
The following table gives a description of the process data structure of the input process data.
Byte
Number
of bytes
Input process data
Description
1
1 byte
DI status
0: DI data not valid.
1-255: DI data valid.
2
1 byte
Padding byte
Do not use
3 … 4
2 byte
DI data
Depends on setting for process data layout: pin-
based or port-based. See next table.
5
1 byte
IO-Link Port 1 data status
0: IO-Link Port 1 input data not valid. 1-
255: IO-Link Port 1 input data valid.
6
1 byte
Padding byte
Do not use
7 … 38
32 byte
IO-Link port 1 process input data
IO-Link input data of the sensor/actor connected to Port
1. For a description of the data, see manual of the
manufacturer of the used sensor/actor.
39
1 byte
IO-Link Port 2 data status
0: IO-Link Port 2 input data not valid. 1-
255: IO-Link Port 2 input data valid.
40
1 byte
Padding byte
Do not use
41 72
32 byte
IO-Link port 2 process input data
IO-Link input data of the sensor/actor connected to Port
2. For a description of the data, see manual of the
manufacturer of the used sensor/actor.
73
1 byte
IO-Link Port 3 data status
0: IO-Link Port 3 input data not valid. 1-
255: IO-Link Port 3 input data valid.
74
1 byte
Padding byte
Do not use